DOI: 10.1615/JLongTermEffMedImplants.v18.i2.40
pages 151-165

Clinical, Surface Damage and Oxidative Performance of Poly II Tibial Inserts After Long-Term Implantation

Francisco Medel
Drexel University
Steven M. Kurtz
Department of Biomedical Engineering, Drexel University, Philadelphia, PA; Exponent Inc., Philadelphia, PA
Gregg R. Klein
Hartzband Center for Hip and Knee Replacement, L.L.C., 10 Forest Avenue, Paramus, NJ 07652, USA
Harlan Levine
Hackensack University Medical Center, Hackensack, NJ
Peter Sharkey
Rothman Institute, 925 Chestnut Street, Philadelphia, PA
Matthew Austin
Rothman Institute, 925 Chestnut Street, Philadelphia, PA
Matthew Kraay
Department of Orthopaedic Surgery, University Hospitals Case Medical Center, Cleveland, OH
Clare M. Rimnac
Musculoskeletal Mechanics and Materials Laboratories, Departments of Mechanical and Aerospace Engineering and Orthopaedics, Case Western Reserve University, Cleveland, OH

ABSTRACT

Carbon fiber−reinforced ultra-high molecular weight polyethylene (Poly II) was clinically introduced in the 1970s, but catastrophic short-term outcomes were reported in case studies. Clinical use of Poly II persisted into the 1980s until it was eventually abandoned. To date, no studies have documented its long-term clinical and material performance. Forty Poly II tibial inserts of the Total Condylar, Insall-Burstein I, and Miller-Galante I designs were retrieved at revision surgery. Twenty-six historical unreinforced polyethylene knee retrievals of similar designs (Miller-Galante I and II, and Insall-Burstein II) served as the control group. The average in vivo durations of both retrieval groups were similar (11.1 and 11.6 years, respectively), although Poly II had a wider implantation range (3.7−32.8 years) than historical polyethylene (4.4−17.0 years). Surface damage on all the retrievals, as well as oxidation and mechanical strength when possible, were characterized. Poly II tibial inserts had long-term clinical survivability and material performance comparable to unreinforced polyethylene bearings. Poly II retrievals exhibited less surface damage at all the regions than historical components, and they were less sensitive to pitting and delamination, but more susceptible to abrasion and embedded debris. Both Poly II and historical retrievals were found to oxidize in vivo and exhibited similar mechanical strength. This study provides improved understanding of well-consolidated Poly II long-term retrievals and also motivation to revisit carbon fiber−reinforced polymeric bearings for joint replacement in the twenty-first century.


Articles with similar content:

Long-Term Results of a Cementless Knee Prosthesis with a Metal-Backed Patellar Component: Clinical and Radiological Follow-Up with Histology from Retrieved Components
Journal of Long-Term Effects of Medical Implants, Vol.13, 2003, issue 4
Mikael Sundfeldt, Tomas Albrektsson, Lars V Carlsson, Carina B. Johansson, Lars Regner
Very Large Diameter Polymer Acetabular Liners Show Promising Wear Simulator Results
Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 4
James Pritchett
Radiographic and Clinical Outcomes Following Robotic-Assisted Lateral Unicompartmental Knee Arthroplasty
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 3
Sean A. Sutphen, Ray C. Wasielewski, David B. Johnson, Jr.
Deformation and Recovery of Thin Metal-Backed, Two-Piece Polyethylene Acetabular Resurfacing Components
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
James Pritchett
Histological Analysis of an Implant Retrieved from a β-Tricalcium Phosphate Graft after 4 Years: A Case Study
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Rolf Ewers, Shadi Daher, Estevam Augusto Bonfante, Joseph Leary, Paulo G. Coelho