图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
器官移植长期效应期刊
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN 打印: 1050-6934
ISSN 在线: 1940-4379

器官移植长期效应期刊

DOI: 10.1615/JLongTermEffMedImplants.2017020207
pages 365-374

A New Design for Maximum Conformity of Total Knee Prosthesis to Femur and Tibia

Ismail Hakki Korkmaz
Department of Mechanical Engineering, Faculty of Engineering, Igdir University, Igdir, Turkey 76000
İrfan Kaymaz
Department of Mechanical Engineering, Faculty of Engineering, Atatürk University, Erzurum, Turkey 25240
Ömer S. Yildirim
Department of Orthopedics and Traumatology, Faculty of Medicine, Atatürk University, Erzurum, Turkey 25240

ABSTRACT

Total knee arthroplasty (TKA) is a common procedure for treating patients with excessively arthritic knees. Nonetheless, early failure of TKA may occur in the first 5 yr, and up to 20% of TKA procedures can fail after 20 yr. In this study, a new anatomic prosthesis was designed to provide maximum conformity to knee bones and produce less stress and strain, in an effort to avoid possible failure of the prosthesis. Anatomical and conventional knee models were compared on the basis of both geometric conformity and stress and strain results obtained from finite element analysis. To compare geometric conformity, anatomic prosthesis components were manufactured by laser melting, and conventional prosthesis components were fixed to sawbone knee models. The anatomical model yielded up to 50% less contact pressure at the insert, which may indicate potential for reduced wear between insert and femur components. This model also resulted in less principal strain value at the tibial component, considered to be an important parameter to indicate loosening. The anatomical model with a new femur component in the anterior cortex design also yielded less stress at the femoral cortex, when compared to the conventional model. The findings in this study suggest that the anatomic prosthesis model may be a better design alternative to conventional knee prostheses in terms of wear, aseptic loosening, and normal joint biomechanics.


Articles with similar content:

A Study on Polyethylene Stresses in Mobile-Bearing and Fixed-Bearing Total Knee Arthroplasty (TKA) using Explicit Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.23, 2013, issue 4
Anindya Deb, Malhar N. Kumar, Gunti Ranga Srinivas
Long-Term Clinical Review (10-20 Years) after Reconstruction of the Anterior Cruciate Ligament Using the Leeds-Keio Synthetic Ligament
Journal of Long-Term Effects of Medical Implants, Vol.17, 2007, issue 1
Graham Sefton, Sameh Sidhom, Alex P. Jones
Biomechanical Analysis of CT Scan-based Hip Prosthesis With an Optimal Hip Ball by Using Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 1
D. Sengupta, U.B. Ghosh, Amit Roychowdhury, S. Pal
Did We Push Dental Ceramics Too Far? A Brief History of Ceramic Dental Implants
Journal of Long-Term Effects of Medical Implants, Vol.15, 2005, issue 6
Fonda G. Robinson, James E. Haubenreich, Robert Q. Frazer, Karen P. West
Metal Sensitivities Among TJA Patients with Post-Operative Pain: Indications for Multi-Metal LTT Testing
Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 1
Edward Solver, Marco S. Caicedo, Nadim James Hallab, Latasha Coleman