The Impact Factor measures the average number of citations received in a particular year by papers published in the journal during the two preceding years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) IF: 2.3 To calculate the five year Impact Factor, citations are counted in 2017 to the previous five years and divided by the source items published in the previous five years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) 5-Year IF: 1.8 The Immediacy Index is the average number of times an article is cited in the year it is published. The journal Immediacy Index indicates how quickly articles in a journal are cited. Immediacy Index: 0.2 The Eigenfactor score, developed by Jevin West and Carl Bergstrom at the University of Washington, is a rating of the total importance of a scientific journal. Journals are rated according to the number of incoming citations, with citations from highly ranked journals weighted to make a larger contribution to the eigenfactor than those from poorly ranked journals. Eigenfactor: 0.00037 The Journal Citation Indicator (JCI) is a single measurement of the field-normalized citation impact of journals in the Web of Science Core Collection across disciplines. The key words here are that the metric is normalized and cross-disciplinary. JCI: 0.6 SJR: 0.433 SNIP: 0.593 CiteScore™:: 4.3 H-Index: 35

Indexed in

HEAT TRANSFER AUGMENTATION OF A TRANSFORMER OIL FLOW IN A SMOOTH TUBE BY EHD EFFECT UNDER HIGH TEMPERATURES

卷 18, 册 2, 2011, pp. 107-114
DOI: 10.1615/JEnhHeatTransf.v18.i2.20
Get accessGet access

摘要

An experimental investigation was performed to understand the electrohydrodynamic (EHD) enhancing effect on laminar forced convective heat transfer of transformer oil. The experiment was carried out in a horizontally positioned smooth tube with an inner diameter of 30 mm under high-temperature conditions. Experimental results show that a high electric voltage applied can exert a strong enhancing effect on the heat transfer, but will cause only small augmentation on the friction factor. The heat transfer enhancement increases rapidly with the increase of the electric voltage applied, and then it seems gradually to approach a saturated maximum value. Also, the oil temperature has a great influence on the heat transfer enhancement and the enhancement ratio increases with the increase of the oil temperature. The average enhancement ratio of the heat transfer coefficient can exceed 6 under 8.0 kV voltages applied, while that of the average friction factor approaches only 1.5.

对本文的引用
  1. Wang Ping-Yang, Liu Jin-Ming, Liu Zhen-Hua, Chen Yan-Jun, Experiment and simulation of natural convection heat transfer of transformer oil under electric field, International Journal of Heat and Mass Transfer, 115, 2017. Crossref

  2. Saha Sujoy Kumar, Ranjan Hrishiraj, Emani Madhu Sruthi, Bharti Anand Kumar, Electrode Design and Its Placement, Enhancement of Single-Phase Gas and Liquid Flow, Theoretical Studies, in Electric Fields, Additives and Simultaneous Heat and Mass Transfer in Heat Transfer Enhancement, 2020. Crossref

  3. Qiu Chengxu, Zhou Weixing, Long Lin, Lv Pengyi, Martynenko Sergey, Yanovskiy Leonid, Forced convection heat transfer of aviation kerosene enhanced by electric field in a circular channel, Applied Thermal Engineering, 197, 2021. Crossref

  4. Chen Yanjun, Wang Zhoumiao, Luo Pingshan, Li Jianping, He Deqiang, Experimental study of natural convection heat transfer characteristics affected by electrical field with periodically changed direction, International Journal of Thermal Sciences, 179, 2022. Crossref