DOI: 10.1615/JEnhHeatTransf.v14.i4.50
pages 315-332

Numerical Design of an Efficient Wavy Fin Surface Based on the Local Heat Transfer Coefficient Study

Y. B. Tao
State Key Laboratory of Multiphase Flow in Power Engineering, School of Energy & Power Engineering, Xi'an Jiaotong University, Xi'an Shaanxi 710049, China
Ya-Ling He
Key Laboratory of Thermo-fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
Z. G. Wu
State Key Laboratory of Multiphase Flow in Power Engineering, School of Energy & Power Engineering, Xi'an Jiaotong University, Xi'an Shaan xi 710049, China
Wen-Quan Tao
State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science & Engineering, Tongji University, Shanghai 200092, China; Key Laboratory of Thermo-Fluid Science and Engineering of MOE, School of Energy and Power Engineering, Xian Jiaotong University, Xian 710049, China

ABSTRACT

In this paper, a 3D numerical investigation of the air side performance of the wavy fin surface is presented with the body-fitted coordinates. Results from local Nusselt number distributions on the whole wavy fin and plain plate fin surfaces show that the local Nusselt number decreases quickly along the flow direction and the values at the upstream are about 10 times of those at the downstream. Based on the results, a new type of the fin surface pattern with a wave located only in the upstream part (fin B) is proposed, and then the comparison of the new fin pattern with the whole wavy fin (fin A) and whole plain plate fin (fin C) is presented. The results show that within the range of the Reynolds number studied, the Nusselt number for fin B is only about 4% lower than for fin A and about 45% higher than for fin C; but the friction factor of fin B is about 18% lower than for fin A and only about 26% higher than for fin C. The comparison at the identical Re number shows that fin B has the best comprehensive performance among the three types of fins, followed by fin C and fin A. Within the range of the Re number studied, compared to fin C, the increased percentage of Nu/f of fin B ranges from 12.4% to 18.5%; compared to fin A, this percentage varies from 14.9% to 20%. It also can be seen that under the identical pressure drop constraint, fin B has the best performance too, followed by fin A and fin C. And under the identical pumping power constraint, fin B has the similar performances to fin A, and both of them are superior to fin C.


Articles with similar content:

Wave Phase based Conditional Sampling of Reynolds Stresses in the Coastal Ocean Bottom Boundary Layer
TSFP DIGITAL LIBRARY ONLINE, Vol.4, 2005, issue
Roi Gurka, Weihong Zhu, Thomas R. Osborn, Joseph Katz, W. A. M. Nimmo Smith, Luksa Luznik
Heat Transfer and Fluid Flow in Rectangular Fin and Elliptic Tube Heat Exchangers under Dry and Dehumidifying Conditions
Journal of Enhanced Heat Transfer, Vol.11, 2004, issue 1
Shin-Li Chen, Jiin-Yuh Jang
NUMERICAL ANALYSIS OF THE THERMAL PERFORMANCE OF A NOVEL DOUBLE-LAYERED HEAT SINK WITH STAGGERED PIN FINS
Heat Transfer Research, Vol.50, 2019, issue 8
Tianqi Zhai, Shengnan Shen, Mingliang Xu, Hui Li, Guoqing Zhang, Yongbo Xue, Yicang Huang
An Experimental Investigation of the Performance of Cross-Corrugated Plate Heat Exchangers
Journal of Enhanced Heat Transfer, Vol.10, 2003, issue 4
Mir-Akbar Hessami
AIRSIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SINE WAVE OR SINE WAVE-SLIT FINS
Journal of Enhanced Heat Transfer, Vol.20, 2013, issue 1
Nae-Hyun Kim, Baek Youn