图书馆订阅: Guest
等离子医学

每年出版 4 

ISSN 打印: 1947-5764

ISSN 在线: 1947-5772

SJR: 0.216 SNIP: 0.263 CiteScore™:: 1.4 H-Index: 24

Indexed in

A Microsecond-Pulsed Cold Plasma Jet for Medical Application

卷 6, 册 2, 2016, pp. 179-191
DOI: 10.1615/PlasmaMed.2016019251
Get accessDownload

摘要

A homemade cold plasma jet device for medical application is introduced here. It consists of a microsecond-pulsed power source and a handheld jet gun. The pulse width is 1.2 μs, and the average plasma power is <10 W. Both helium (He) and argon (Ar) gas were used to generate touchable cold plasma jet, and the maximum jet lengths were 7 cm and 3 cm, respectively. Pulsed voltage and gas flow have significant influence onjet formation. The emission spectra of the He and Arjets were compared. When Staphylococcus aureus was treated on a 90-mm agar plate for 0.5−2.5 min, bactericidal spots of 0.5−5.0 cm were obtained. In terms of disinfection of Staphylococcus aureus on a 10-mm quartz plate, Ar plasma performs more efficiently than He plasma.

对本文的引用
  1. DENG Guanlei, JIN Qikang, YIN Shengyong, ZHENG Chao, LIU Zhen, YAN Keping, Experimental study on bacteria disinfection using a pulsed cold plasma jet with helium/oxygen mixed gas, Plasma Science and Technology, 20, 11, 2018. Crossref

  2. YAN Keping, JIN Qikang, ZHENG Chao, DENG Guanlei, YIN Shengyong, LIU Zhen, Pulsed cold plasma-induced blood coagulation and its pilot application in stanching bleeding during rat hepatectomy, Plasma Science and Technology, 20, 4, 2018. Crossref

  3. Wang Xiao-Feng, Fang Qing-Qing, Jia Bing, Hu Yan-Yan, Wang Zheng-Cai, Yan Ke-ping, Yin Sheng-Yong, Liu Zhen, Tan Wei-Qiang, Potential effect of non-thermal plasma for the inhibition of scar formation: a preliminary report, Scientific Reports, 10, 1, 2020. Crossref

  4. Jia Bing, Liu Jingfeng, Yin Shengyong, Liu Zhen, Zheng Shusen, Yan Keping, Low Temperature Plasma Treatment of Rat Blood is Accompanied by Platelet Aggregation, Plasma Chemistry and Plasma Processing, 41, 4, 2021. Crossref

806 文章浏览量 1209 文章下载 统计数据
806 文章浏览量 1209 下载次数 4 Crossref 引用次数 Google
Scholar
引用次数

相似内容的文章:

Analysis of the Effects of Disinfectants and Plasma Treatment on Biofilm Growth by a Thermal Flow Sensor for Real-Time Measurements Plasma Medicine, Vol.12, 2022, issue 2
Krishan Kotthaus, Michael E. Bergmann, Tobias Wieland, Elena I. Bürkin, Florian Engesser, Loïc Ledernez, Gerald A. Urban, Markus J. Altenburger
Plasma Medicine in Dermatology: Basic Antimicrobial Efficacy Testing as Prerequisite to Clinical Plasma Therapy Plasma Medicine, Vol.2, 2012, issue 1-3
Sebastian Scholz, Steffen Emmert, Michael Junger, Hermann Haase, Sebastian von Podewils, Georg Daeschlein, Thomas von Woedtke
Air-Based Coaxial Dielectric Barrier Discharge Plasma Source for Pseudomonas aeruginosa Biofilm Eradication Plasma Medicine, Vol.7, 2017, issue 1
Diana Grondona, Leandro Giuliani, Juliana Soler-Arango, Magali Xaubet, Graciela Brelles-Mariño
Low-Temperature Plasma: An Effective Approach Against Candida albicans Biofilm Plasma Medicine, Vol.4, 2014, issue 1-4
Xi Wei, Myrella Lessio Castro, Wirley Goncalves Assuncao, Simone Duarte, Ramiro Mendonca Murata, Juliana Aparecida Delben, Nelson Renato Franca Alves da Silva
Action of an Argon/Water Vapor Plasma Jet in the Sterilization of Silicone Contaminated with Candida albicans Plasma Medicine, Vol.7, 2017, issue 3
Jhonatan Steffens Brandao Lima, Homero Santiago Maciel, Fernanda Ramos Figueira, Anelise C.O.C. Doria, Ligia Satiko Simomura, Sonia Khouri, Guilherme Torello Cassiano Redi, Rodrigo Savio Pessoa
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集 订购及政策 Begell House 联系我们 Language English 中文 Русский Português German French Spain