图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
雾化与喷雾
影响因子: 1.262 5年影响因子: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN 打印: 1044-5110
ISSN 在线: 1936-2684

卷:
卷 29, 2019 卷 28, 2018 卷 27, 2017 卷 26, 2016 卷 25, 2015 卷 24, 2014 卷 23, 2013 卷 22, 2012 卷 21, 2011 卷 20, 2010 卷 19, 2009 卷 18, 2008 卷 17, 2007 卷 16, 2006 卷 15, 2005 卷 14, 2004 卷 13, 2003 卷 12, 2002 卷 11, 2001 卷 10, 2000 卷 9, 1999 卷 8, 1998 卷 7, 1997 卷 6, 1996 卷 5, 1995 卷 4, 1994 卷 3, 1993 卷 2, 1992 卷 1, 1991

雾化与喷雾

DOI: 10.1615/AtomizSpr.v12.i123.70
pages 123-143

STABILITY BOUNDARIES OF LAMINAR PREMIXED POLYDISPERSE SPRAY FLAMES

J. Barry Greenberg
Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa, 32000, Israel

ABSTRACT

A simple model of a flame front propagating through a fuel-rich droplet—vapor—air mixture is presented. An arbitrary polydisperse size distribution of droplets in the spray is allowed. The droplets are permitted to vaporize at a finite rate so that their interaction with and possible traversal of the flame front is accounted for. Steady-state solutions are established by means of large activation energy asymptotics. An analysis of instability to transverse perturbations is then carried out in order to determine neutral stability boundaries.
Two initial droplet size distributions having the same Sauter mean diameter (SMD) are considered. One is initially quasi-monodisperse (A), whereas the second is bimodal (B). It is found that the onset of flame cellularization is sensitive to the initial droplet size distribution in the spray. Specifically, under certain operating conditions, the flame resulting from distribution A is cellular, whereas that of distribution B is stable. Under other conditions, in which both spray flames are unstable, the cellular structure of flame A is found to be finer than that of flame B. These results indicate that use of the SMD to characterize a spray in the context of cellular flame instability may lead to mistaken conclusions. However, the location of the pulsating stability boundaries was found to be rather insensitive to the initial droplet distribution and, indeed, to the presence of the droplets. In addition, it lay beyond the practical range of Lewis numbers relevant to these rich flames.


Articles with similar content:

FLAME STRUCTURE OF LIQUID-FUELLED CYCLONE COMBUSTORS
ICLASS 94
Proceedings of the Sixth International Conference on Liquid Atomization and Spray Systems, Vol.0, 1994, issue
A.A. Aref, S.S. Wahid
EFFECT OF A FUEL SPRAY ON EDGE FLAME PROPAGATION
Atomization and Sprays, Vol.22, 2012, issue 4
Leonid S. Kagan, J. Barry Greenberg, G. I. Sivashinsky
STRUCTURE OF VAPORIZING PRESSURE ATOMIZED SPRAYS
Atomization and Sprays, Vol.3, 1993, issue 3
G. Scott Samuelsen, Vincent McDonell
EXPERIMENTS ON AIR-ASSIST SPRAY AND SPRAY FLAMES
Atomization and Sprays, Vol.11, 2001, issue 6
Min Su Paek, Sang Heun Oh, Dong Il Kim
SENSITIVITY OF PULSATING ORGANIC GEL POLYDISPERSE SPRAY DIFFUSION FLAMES TO EVAPORATION FREQUENCY DROPLET-SIZE DEPENDENCY
Atomization and Sprays, Vol.19, 2009, issue 6
J. Barry Greenberg, Benveniste Natan, A. Kunin