图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
雾化与喷雾
影响因子: 1.262 5年影响因子: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN 打印: 1044-5110
ISSN 在线: 1936-2684

卷:
卷 29, 2019 卷 28, 2018 卷 27, 2017 卷 26, 2016 卷 25, 2015 卷 24, 2014 卷 23, 2013 卷 22, 2012 卷 21, 2011 卷 20, 2010 卷 19, 2009 卷 18, 2008 卷 17, 2007 卷 16, 2006 卷 15, 2005 卷 14, 2004 卷 13, 2003 卷 12, 2002 卷 11, 2001 卷 10, 2000 卷 9, 1999 卷 8, 1998 卷 7, 1997 卷 6, 1996 卷 5, 1995 卷 4, 1994 卷 3, 1993 卷 2, 1992 卷 1, 1991

雾化与喷雾

DOI: 10.1615/AtomizSpr.2015013972
pages 961-982

A COMPARISON OF DIESEL AND JATROPHA METHYL ESTER (JME) SPRAY CHARACTERISTICS: EFFECT OF NOZZLE ENTRY RADIUS

Prasad Boggavarapu
Combustion and Spray Laboratory, Department of Mechanical Engineering, Indian Institute of Science, Bangalore-12, India
R. V. Ravikrishna
Combustion & Spray Laboratory, Department of Mechanical Engineering, Indian Institute of Science, Bangalore, 560012, India

ABSTRACT

In the present article, diesel and Jatropha methyl ester (JME) sprays are compared in a detailed manner in terms of their macroscopic and microscopic spray characteristics. The comparison is made at injection pressures of 500,1000, and 1500 bar by injecting the fuels through a nozzle having a single hole of 200 µm diameter and 70 µm entry radius into a spray chamber (with optical access). From the measurements of macroscopic spray structure, it is observed that the spray tip penetration is faster and spray cone angle is narrower by approximately 10% for JME than those of diesel, indicating that the JME spray atomization is poor. Droplet sizes are measured for diesel and JME sprays at 4 ms after the start of injection using particle/droplet image analysis, which showed that the Sauter mean diameter (SMD) of JME sprays is higher by around 5% as compared to that of diesel. Subsequently, a nozzle with a hole diameter of approximately 200 µm having an entry radius of10 µm is studied to understand the effect of nozzle entry radius on breakup of diesel and JME sprays. Computational fluid dynamic modeling of inner-nozzle flow showed that there is significant inner-nozzle cavitation for this nozzle. A comparison of spray structure at injection pressures of 500 and 1500 bar showed that the spray tip penetration is slower and spray cone angles are wider by approximately 5% to 12% for sprays from the cavitating nozzle than those from the noncavitating nozzle. Droplet size comparison showed that SMD of spray from the cavitating nozzle is lower by approximately 5% as compared to that from the noncavitating nozzle. Thus improvement in spray atomization due to inner-nozzle cavitation may be able to compensate for the inferior atomization of JME, although with an associated penalty in the coefficient of discharge.


Articles with similar content:

EXPERIMENTAL STUDIES ON HIGH-PRESSURE SPRAY STRUCTURE OF BIOFUELS
Atomization and Sprays, Vol.21, 2011, issue 6
R. V. Ravikrishna, Devendra Deshmukh
HOLOGRAPHIC INVESTIGATION OF MICROEXPLOSION IN AN EMULSIFIED DIESEL OIL SPRAY
Atomization and Sprays, Vol.3, 1993, issue 2
H. Xu, Dimos Poulikakos, C. G. Zhu, Y. B. Shen
A STUDY OF THE FLOW AND ATOMIZATION CHARACTERISTICS OF IMPINGED DIESEL SPRAY ON A CHAMBER WALL
Atomization and Sprays, Vol.17, 2007, issue 7
Chang Sik Lee, Sungwook Park, Hyun Kyu Suh
EXPERIMENTAL STUDY ON SPRAY ANGLE AND VELOCITY DISTRIBUTION OF DIESEL SPRAY UNDER HIGH AMBIENT PRESSURE CONDITIONS
Atomization and Sprays, Vol.21, 2011, issue 12
Masataka Arai, Yoshio Zama, Wataru Ochiai, Tomohiko Furuhata
INFLUENCE OF FUEL PROPERTIES ON THE DIESEL INJECTION PROCESS IN NONVAPORIZING CONDITIONS
Atomization and Sprays, Vol.22, 2012, issue 6
Christine Mounaim-Rousselle, S. Houille, Hespel Camille, Fabrice Foucher, J. Dernotte