图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
雾化与喷雾
影响因子: 1.262 5年影响因子: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN 打印: 1044-5110
ISSN 在线: 1936-2684

卷:
卷 29, 2019 卷 28, 2018 卷 27, 2017 卷 26, 2016 卷 25, 2015 卷 24, 2014 卷 23, 2013 卷 22, 2012 卷 21, 2011 卷 20, 2010 卷 19, 2009 卷 18, 2008 卷 17, 2007 卷 16, 2006 卷 15, 2005 卷 14, 2004 卷 13, 2003 卷 12, 2002 卷 11, 2001 卷 10, 2000 卷 9, 1999 卷 8, 1998 卷 7, 1997 卷 6, 1996 卷 5, 1995 卷 4, 1994 卷 3, 1993 卷 2, 1992 卷 1, 1991

雾化与喷雾

DOI: 10.1615/AtomizSpr.2016013897
pages 1051-1067

THE EFFECT OF DIFFERENT COOLING UNIT CONFIGURATIONS AND COOLING TEMPERATURES ON GLASS TEMPERING QUALITY

Mehmet Akcay
Technical Education Faculty, Mechanical Education Department, Pamukkale University, Denizli, Turkey
Hilmi Yazici
Technology Faculty, Automotive Engineering Department, Pamukkale University, Denizli, Turkey
Mustafa Golcu
Technology Faculty, Automotive Engineering Department, Pamukkale University, Denizli, Turkey
Yakup Sekmen
Engineering Faculty, Mechanical Engineering Department, Karabuk University, Karabuk, Turkey

ABSTRACT

In this study, an auto glass tempering process was conducted in different cooling unit configurations and cooling temperatures, and the changes in the sudden cooling time and the number of broken glass particles of the tempered glass plates were examined. Six-millimeter-thick glass plates were heated up to Th = 680°C and then suddenly cooled at four different cooling temperatures (Tc = 70, 250, 300, and 400°C). In the sudden cooling process, the rate of the distance between nozzle axes to nozzle diameter (S/D) was taken as 4 ≤ S/D ≤ 8, the rate of the distance to the glass surface to nozzle diameter (H/D) was taken as 2 ≤ H/D ≤ 8, and the Reynolds number was kept constant at Re = 20,000. According to the results revealed in the study, as the S/D and H/D rates increased, the cooling time increased and the number of particles decreased. It was found that the sudden cooling time and the number of particles changed in inverse proportion to the cooling temperature. When the cooling temperature was decreased from 250°C to 70°C for each cooling unit configuration (S/D = 4, 6, and 8), there was a high increase in the cooling time, whereas the increase in the number of particles was quite small.


Articles with similar content:

HEAT TRANSFER AND FLOW CHARACTERISTICS OF ULTRA-MICRO STEAM INJECTOR AND ITS OPERATING CONDITION
International Heat Transfer Conference 16, Vol.7, 2018, issue
Akihiro Futsuta, Yutaka Abe, Akiko Kaneko, Yutaka Suzuki
EFFECT OF PARTICLE SIZE AND SIZE POLYDISPERSITY ON SUPERCOOLING DEGREE OF N-HEPTADECANE MICROCAPSULES
International Heat Transfer Conference 16, Vol.24, 2018, issue
Yiang Li, Ying Chen, Songping Mo, Lisi Jia, Wei Cui, Jun Li
MIXED CONVECTION HEAT TRANSFER IN A DOUBLE LID-DRIVEN INCLINED SQUARE ENCLOSURE SUBJECTED TO Cu−WATER NANOFLUID WITH PARTICLE DIAMETER OF 90 nm
Heat Transfer Research, Vol.45, 2014, issue 1
Seyed Sadegh Mirtalebi Esforjani, Mohammad Hadi Hajmohammad, Mohammad Reza Heydari, Mohammad Akbari, Mohammad Hemmat Esfe
ATMOSPHERIC INDUCTION PLASMA SPRAYING
High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes, Vol.15, 2011, issue 1
Gabriele Nutsch
INVESTIGATION OF FLAME HEIGHT AND JUMP OF FIRE IN VERTICAL ORIENTATION FOR CELLULOSIC MATERIAL
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
Sunil R. Kale, Deepti Gupta, Hitesh Verma