图书馆订阅: Guest
国际流体力学研究期刊

每年出版 6 

ISSN 打印: 2152-5102

ISSN 在线: 2152-5110

The Impact Factor measures the average number of citations received in a particular year by papers published in the journal during the two preceding years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) IF: 1.1 To calculate the five year Impact Factor, citations are counted in 2017 to the previous five years and divided by the source items published in the previous five years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) 5-Year IF: 1.3 The Eigenfactor score, developed by Jevin West and Carl Bergstrom at the University of Washington, is a rating of the total importance of a scientific journal. Journals are rated according to the number of incoming citations, with citations from highly ranked journals weighted to make a larger contribution to the eigenfactor than those from poorly ranked journals. Eigenfactor: 0.0002 The Journal Citation Indicator (JCI) is a single measurement of the field-normalized citation impact of journals in the Web of Science Core Collection across disciplines. The key words here are that the metric is normalized and cross-disciplinary. JCI: 0.33 SJR: 0.256 SNIP: 0.49 CiteScore™:: 2.4 H-Index: 23

Indexed in

Wave Propagation and Reflection in Systems of Compliant

卷 31, 册 6, 2004, pp. 608-620
DOI: 10.1615/InterJFluidMechRes.v31.i6.70
Get accessGet access

摘要

Axisymmetric wave motion of a viscous incompressible liquid in a system, which is consisted of a long thin elastic tube and a terminal element with a complex admittance is investigated. Expression for the input admittance of the system taking into account wave reflection at the end of the tube is obtained. The dependence of the input admittance on geometrical and mechanical parameters of the system is investigated. The equation for calculation the socalled resonant harmonics where the input admittance reaches its extreme is obtained. The harmonics is considered as resonant, when any alteration in terminal admittance causes a significant variation in its amplitude. The influence of variations of the model parameters on the amplitude and the phase of the input admittance is closely investigated. Possible applications of the proposed model for biomechanical interpretation of novel methods of medical pulse diagnosis are discussed.

对本文的引用
  1. Kizilova Natalya, Novel methods of pulse wave diagnostics based on compression of a superficial artery, PAMM, 7, 1, 2007. Crossref

  2. Kizilova Natalya, Optimal long-distance transport systems in nature: control and applications (Poster Presentation), PAMM, 7, 1, 2007. Crossref

Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集 订购及政策 Begell House 联系我们 Language English 中文 Русский Português German French Spain