Calibration of Thin-Wire Platinum Bolometers for Pulsed Laser Power Measurements
ABSTRAKT
A technique is justified for calibrating thin-wire platinum bolometers intended for measurements of pulsed radiation power at the wavelength of 10.6 μ. The technique is based on the use of known temperature dependences of the specific resistance and specific heat capacity for determining the temperature dependence of the absorption efficiency factor. The heat balance equation with variable coefficients is averaged over the bolometer length and then solved for a non-uniform distribution of the incident power.
-
Kuzmichov V.M., Priz I.A., Safronov B.V., Balkashin V.P., Pogorelov S.V., Kohns P., Measuring of the factor of absorption efficiency of thinwire bolometer, Proceedings of CAOL 2005. Second International Conference on Advanced Optoelectronics and Lasers, 2005., 2, 2005. Crossref
-
Kuzmichov V.M., Pogorelov S.V., Kohns P., Measuring of laser radiation polarization state with three profile bolometric gratings, Proceedings of CAOL 2005. Second International Conference on Advanced Optoelectronics and Lasers, 2005., 2, 2005. Crossref