Journal of Long-Term Effects of Medical Implants
Erscheint 4 Ausgaben pro Jahr
ISSN Druckformat: 1050-6934
ISSN Online: 1940-4379
SJR:
0.184
SNIP:
0.485
CiteScore™::
1.1
H-Index:
39
Indexed in
Revolutionary Advances in Skin Stapling: A Collective Review
Volumen 11,
Ausgabe 1&2, 2001,
9 pages
DOI: 10.1615/JLongTermEffMedImplants.v11.i12.80
ABSTRAKT
The purpose of this article is to provide a collective review of the literature on skin staplers. On the basis of this review, the Auto Suture Multifire Premium™, with its regular and wide metal staples, is recommended for skin closure. The Auto Suture Multifire Graftac-S™ is ideally suited for skin-graft fixation, because it delivers an absorbable staple that usually does not have to be removed from the healing graft. Dermal skin closure can now be achieved using the Auto Suture SQS-20™, which coapts the cut dermal edges with an absorbable straight pin. Dermal wound approximation can be accomplished in significantly less time than dermal suture closure.
489 Artikelansichten
16 Artikel-Downloads
Metriken
Artikel mit ähnlichem Inhalt:
Neueste Ausgabe
Zukünftige Artikel
Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report.
Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients
Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant
The history of orthopedics in the long term: from general medicine to medical specialties
COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS
CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS
C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization
COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY
FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework
Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB
Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty.
The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study
ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY