Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Long-Term Effects of Medical Implants
SJR: 0.332 SNIP: 0.491 CiteScore™: 0.89

ISSN Druckformat: 1050-6934
ISSN Online: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v17.i4.70
pages 335-342

Designing Suitable Sizes of Hip Implants for Indian Patients

Palash Kumar Maji
CSIR-Central Mechanical Engineering Research Institute, Durgapur, India
Partha Sarathi Banerjee
Central Mechanical Engineering Research Institute, Durgapur
Anupam Sinha
Central Mechanical Engineering Research Institute, Durgapur

ABSTRAKT

A large number of orthopaedically handicapped patients in India require treatment with suitable low-cost implants of varied sizes and shapes, which has become a crucial problem today. Out of these patients, the case of degenerative hip joints is around one-half million every year, the majority of which are total hip replacements. For most of these cases, the surgery is done with imported implants, which may not be in keeping with the osteological dimensions of Indian patients. To explore this area, a study was done at CMERI on computed tomographic (CT) scan data of the proximal region of the femur bone of patients from different regions of India. Since the problem is prominent with the elderly populations who are above 50 years of age, the CT scan data was collected for patients with age of 50−78 years. In this study, 23 selected osteological dimensions of each femur were measured in a CAD environment from CT scan data of around 100 elderly Indian patients. The measured parameters were statistically analyzed to find out the variations and stepping of dimensions. Depending on these data, the stem of hip implant was designed with different sizes, suitable for Indian patients. The devices were then analyzed in finite element analysis packages individually, as well as by putting the device inside the femur bone, as an actual case. After this analysis, some modifications were required and it was found that after implantation the stress induced in the implant and bone would be well within permissible limits.


Articles with similar content:

Proposed Frequencies of a Vibrator Used for Implant Retrieval at the Time of Hip Joint Revision Surgery
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 2
Vijay J. Rasquinha, Westley T. Hayes, Amit Roychowdhury
Influences of Stresses on Dental Implant Threads Using Finite-Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Masud Rana, Vinamra Jain, Vamsi Krishna Dommeti, Sandipan Roy
Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 1
Raheleh Akhavan Rasoolzadeh, Mahdi Kadkhodazadeh, Amir Mahmoudi Motlagh, Farshad Dehnavi, Reza Amid
Comparison of the Effects of Different Implant Apical Designs on the Magnitude and Distribution of Stress and Strain in Bone: A Finite Element Analysis Study
Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 2-3
Hasti Torabi, Mohammad Reza Movahhedy, Ardeshir Lafzi, Saeed Raoofi, Mahdi Kadkhodazadeh, Maryam Khademi, Reza Amid
Clinical Evaluation of a New Total Hip Prosthetic Design: 100 Consecutive Cementless Total Hip Arthroplasties Using Sulzermedica's "Natural Hip" With Two- to Six-Year Clinical and Radiographic Follow-Up
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Thomas B. Pace