Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 0.404 5-jähriger Impact-Faktor: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2013006189
pages 665-686

TRIPLE TUBE AMMONIA EVAPORATOR DESIGN FOR DOMESTIC ABSORPTION REFRIGERATORS

Ahmed Mohammed Adham
Erbil Polytechnic University
Normah Mohd-Ghazali
Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Barhru, Malaysia
Mikdam M. Saleh
Power Engineering Department, College of Engineering, University of Baghdad, Al‐Jadriya, Baghdad, Iraq
Robiah Ahmad
UTM Razak School of Engineering and Advanced Technology, Universiti Teknologi Malaysia International campus, 54100 Jalan Semarak, Kuala Lumpur, Malaysia

ABSTRAKT

A usable concept for an ammonia evaporator in an absorption refrigerator based on a triple tube design is considered. The differential equations that describe the energy transfer between the ammonia refrigerant and the ammonia hydrogen gas mixture are utilized to simulate the thermal and hydrodynamic performances and hence to determine the operation of evaporator. This simulation procedure is used to determine the geometrical parameters of the evaporator, subject to certain optimization criteria that were incorporated in a cost function. The final design of the evaporator, which is based on 100 W of cooling power at −6.7 °C, has a length of 1.523 m and triple tube diameters of 28.5, 22.2, and 15.8 mm. The evaporator's design is such that only a single penetration through the refrigerator's wall is necessary, which greatly simplifies the construction and reduces its cost.


Articles with similar content:

SPRAY EVAPORATION
Atomization and Sprays, Vol.12, 2002, issue 1-3
Milan Marcic
TRANSITIONAL INSTABILITY OF A PRESSURE-SWIRL ATOMIZER DUE TO AIR-CORE ERUPTION AT LOW TEMPERATURE
Atomization and Sprays, Vol.17, 2007, issue 6
Sam S. Yoon, Byung-Sung Park, Ho Young Kim
NEW TYPE OF EVAPORATOR FOR LOOP HEAT PIPE
Second Thermal and Fluids Engineering Conference, Vol.20, 2017, issue
Alexander Yakomaskin
FEASIBILITY STUDY OF NEW HEAT TRANSPORTATION SYSTEM WITH DRAG-REDUCING SURFACTANT ADDITIVES
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Akira Yabe, Pei-Wen Li, Yasuo Kawaguchi
MODELING THE EFFECTIVE DYNAMIC PROPERTIES OF FIBER COMPOSITES MODIFIED ACROSS LENGTH SCALES
Nanoscience and Technology: An International Journal, Vol.9, 2018, issue 2
G. I. Kriven, Sergey A. Lurie, Dmitriy B. Volkov-Bogorodsky