Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 1.199 5-jähriger Impact-Faktor: 1.155 SJR: 0.267 SNIP: 0.503 CiteScore™: 1.4

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 51, 2020 Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2012004228
pages 523-538

Experimental Investigation of Thermal Response on High-Vacuum-Multilayer-Insulation (HVMLI) Cryogenic Tank after Sudden, Catastrophic Loss of Insulation Vacuum (SCLIV)

Ming Zhu
Department of Mechanics & Power, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, No. 800,Dongchuan Road, Shanghai 200240, PR China
C. Ding
Department of Mechanics & Power, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, No. 800,Dongchuan Road, Shanghai 200240, PR China
R. S. Wang
Department of Mechanics & Power, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, No. 800,Dongchuan Road, Shanghai 200240, PR China

ABSTRAKT

This paper was to experimentally investigate the thermal response of high-vacuum-multilayer-insulation (HVMLI) cryogenic tank after sudden, catastrophic loss of insulation vacuum (SCLIV). The venting and no-venting experiments were conducted with the breakdown of the insulating vacuum with nitrogen. There was a great temperature gradient in the thickness direction of the MLI in both the venting and no-venting experiments. Temperature jump appeared on the external wall of the inner vessel after gas was introduced into the insulation vacuum jacket. Thermal stratification in liquid nitrogen (LN2) was serious with 25 K axial temperature difference in the no-venting experiment. The no-venting experiment included four stages. The fourth stage was the most dangerous and must be strictly avoided because the pressure of the tank full of superheated LN2 could surpass the safety pressure in a few minutes and the tank could blast at any moment.


Articles with similar content:

STEADY STATE MOLE FRACTION DISTRIBUTION OF A SLOW JET FORMING STABLY STRATIFIED FIELD
ICHMT DIGITAL LIBRARY ONLINE, Vol.18, 1992, issue
Motoo Fumizawa
APPLICATION OF DOWNDRAFT COMBUSTION TO WOODBURNING DEVICES
International Heat Transfer Conference 9, Vol.6, 1990, issue
K. Krishna Prasad, P. Verhaart , R. Khan, E. Schutte, A.M. Hasan
Simulation of gas flow field of an air blast swirler fuel injector with LES and comparison with experiments
TSFP DIGITAL LIBRARY ONLINE, Vol.1, 1999, issue
J. Holmborn, Laszlo Fuchs, C. Troger
Simulation of gas flow field of an air blast swirler fuel injector with LES and comparison with experiments
Turbulence and Shear Flow Phenomena -1 First International Symposium, Vol.0, 1999, issue
J. Holmborn, Laszlo Fuchs, C. Troger
STUDY OF THERMO-MECHANICAL DEFORMATION OF SCALED DOWN FUEL CHANNEL UNDER HEATUP
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
Deb Mukhopadhyay, Prasanna Majumdar, Ankit R. Singh, Pradeep Kumar Sahoo