Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 0.404 5-jähriger Impact-Faktor: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2012004228
pages 523-538

Experimental Investigation of Thermal Response on High-Vacuum-Multilayer-Insulation (HVMLI) Cryogenic Tank after Sudden, Catastrophic Loss of Insulation Vacuum (SCLIV)

Ming Zhu
Department of Mechanics & Power, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, No. 800,Dongchuan Road, Shanghai 200240, PR China
C. Ding
Department of Mechanics & Power, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, No. 800,Dongchuan Road, Shanghai 200240, PR China
R. S. Wang
Department of Mechanics & Power, Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, No. 800,Dongchuan Road, Shanghai 200240, PR China

ABSTRAKT

This paper was to experimentally investigate the thermal response of high-vacuum-multilayer-insulation (HVMLI) cryogenic tank after sudden, catastrophic loss of insulation vacuum (SCLIV). The venting and no-venting experiments were conducted with the breakdown of the insulating vacuum with nitrogen. There was a great temperature gradient in the thickness direction of the MLI in both the venting and no-venting experiments. Temperature jump appeared on the external wall of the inner vessel after gas was introduced into the insulation vacuum jacket. Thermal stratification in liquid nitrogen (LN2) was serious with 25 K axial temperature difference in the no-venting experiment. The no-venting experiment included four stages. The fourth stage was the most dangerous and must be strictly avoided because the pressure of the tank full of superheated LN2 could surpass the safety pressure in a few minutes and the tank could blast at any moment.


Articles with similar content:

EXPERIMENTAL INVESTIGATION ON PRESSURE OSCILLATIONS CAUSED BY CONDENSATION INDUCED WATER HAMMER IN A HORIZONTAL PIPE
3rd Thermal and Fluids Engineering Conference (TFEC), Vol.29, 2018, issue
Weixiong Chen, Xiaoyu Yue, Daotong Chong, Lutao Wang, Junjie Yan
Experimental and Theoretical studies of Time-Dependent Buoyancy Driven Flow
International Heat Transfer Conference 10, Vol.18, 1994, issue
Michael J. Tierney, T. Reg Bott, G. L. Quarini
THERMAL STRATIFICATION IN NUCLEAR REACTOR PIPING SYSTEM
International Heat Transfer Conference 13, Vol.0, 2006, issue
Moyses Alberto Navarro, Hugo Cesar Rezende, Andre Augusto Campagnole dos Santos
DISCHARGE OF SATURATED WATER THROUGH PIPES AND ORIFICES
International Heat Transfer Conference 3 , Vol.17, 1966, issue
Hideo Uchida , Hideki Nariai
Transient Heat Transfer to a Forced Flow of Supercritical Helium at Very Low Temperatures
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 1986, issue
W. B. Bloem