Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v42.i2.40
pages 143-164

Influence of Internal Cyclone Flow on Adiabatic Film Cooling Effectiveness

Andreas Lerch
Institute of Gas Turbines and Aerospace Propulsion, Technische Universität Darmstadt, 64287 Darmstadt, Germany
Heinz-Peter Schiffer
Institute of Gas Turbines and Aerospace Propulsion, Technische Universität Darmstadt, 64287 Darmstadt, Germany

ABSTRAKT

The adiabatic film cooling effectiveness on the surface of a symmetrical blade model was measured for eight cylindrical, 59° inclined cooling holes. The holes were fed with different flow types using a cylindrical leading-edge channel. Two configurations were compared: on the one hand, a leading-edge channel flow without swirl (datum configuration), using a sharp-edged inlet; on the other hand, a new cyclone cooling configuration with a positive swirl. The experiments were carried out using the calibrated ammonia diazo technique. The blowing ratios were varied between 0.6 and 1.2, and the film cooling discharge was set to either 20% or 50%. For all these operation points, multiple experiments were conducted and combined using a weighting average method to produce a high full-range resolution. The lateral and area-averaged adiabatic effectiveness is presented up to 45D downstream of the cooling holes. The measurements show a higher area-averaged effectiveness immediately downstream of the cooling holes when using the cyclone cooling configuration. This is due to nonsymmetric flow structures inside the cooling holes. Further downstream, however, it decreases faster. With a low film cooling discharge and rising blowing ratios, these effects are more pronounced.


Articles with similar content:

INFLUENCE OF INTERNAL CYCLONE FLOW ON ADIABATIC FILM COOLING EFFECTIVENESS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Heinz-Peter Schiffer, Andreas Lerch
EFFECT OF ANTI-VORTEX HOLE ANGLE ON THE FILM COOLING EFFECTIVENESS
Heat Transfer Research, Vol.48, 2017, issue 6
Jae Su Kwak, Younggi Moon, Soon Sang Park, Jung Shin Park
A COMPARATIVE STUDY OF THE FILM COOLING HOLE CONFIGURATION EFFECTS ON THE LEADING EDGE OF ASYMMETRICAL TURBINE BLADE
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Abbes Azzi, B. A. Jubran, Mustapha Benabed
NUMERICAL INVESTIGATION OF FILM-COOLING EFFECTIVENESS DOWNSTREAM OF A MICRO RAMP
Computational Thermal Sciences: An International Journal, Vol.10, 2018, issue 2
Zakaria Mansouri, Abbes Azzi, Hamza Khamane
FILM COOLING FROM TWO ROWS OF HOLES WITH OPPOSITE ORIENTATION ANGLES: INJECTANT BEHAVIORS
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Joon Ahn, In Sung Jung, Joon Sik Lee