Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 0.404 5-jähriger Impact-Faktor: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2012005855
pages 573-590

NUMERICAL PREDICTIONS OF PRESSURE DROP AND HEAT TRANSFER IN A BLADE INTERNAL COOLING PASSAGE WITH CONTINUOUS/TRUNCATED RIBS

Shian Li
Engineering Simulation and Aerospace Computing (ESAC), Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Northwestern Polytechnical University, Xi'an, 710072, Shaanxi, China; Department of Energy Sciences, Lund University
Gongnan Xie
Department of Mechanical and Power Engineering, Northwestern Polytechnical University, Xi'an, 710072, Shaanxi, China
Weihong Zhang
Laboratory of Engineering Simualtion and Aerospace Computing (ESAC), Northwestern Polytechnical University, P.O.Box 552, 710072, Xi'an, Shaanxi, China
Bengt Sunden
Division of Heat Transfer, Department of Energy Sciences, Lund University, P.O. Box 118, SE-22100, Lund, Sweden

ABSTRAKT

Ribs are often used in the mid-section of internal turbine blades to augment heat transfer from the blade wall to a coolant, but most research works are concerned only with continuous ribs attached to the side walls. In this paper, a turbulent flow and heat transfer of a rectangular passage with continuous and truncated ribs on opposite walls have been predicted numerically. Two types of ribs are studied: 90-deg ribs and 45-deg V-shaped ribs. The inlet Reynolds numbers range from 12,000 to 60,000. The complex three-dimensional turbulent flows inside the blade internal coolant passage and heat transfer between the rib-walls and side-walls are presented. The overall performances of six different ribbed passages are evaluated and compared. Numerical results show that the passage with truncated V-shaped ribs is very effective in improving the heat transfer performance with a low pressure drop.


Articles with similar content:

Aero-thermal simulation in a square ribbed duct
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Odile Labbe
EXPERIMENTAL STUDY OF PRESSURE DROP AND HEAT TRANSFER IN A U-BEND CHANNEL WITH VARIOUS GUIDE VANES AND RIBS
Journal of Enhanced Heat Transfer, Vol.22, 2015, issue 1
Alfonso Niro, Lei Wang, Susanna Cimina, Bengt Sunden, Chenglong Wang
Pressure loss and wall heat transfer characteristics in blade trailing-edge cooling passage
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2012, issue
Yufeng Yao, M. Effendy, Jun Yao
NUMERICAL SOLUTION OF FLUID FLOW AND CONJUGATE HEAT TRANSFER IN A CHANNEL FILLED WITH FIBROUS POROUS MEDIA-A LATTICE BOLTZMANN METHOD APPROACH
Journal of Porous Media, Vol.17, 2014, issue 12
Abbas Abbassi, Alireza Salehi, Mohsen Nazari
THERMAL VISUALIZATION AND PERFORMANCE EVALUATION OF THE OPEN MATRIX STRUCTURES USING LIQUID CRYSTAL THERMOGRAPHY
Journal of Flow Visualization and Image Processing, Vol.25, 2018, issue 3-4
Andallib Tariq, Anjana Prajapati