Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 0.404 5-jähriger Impact-Faktor: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018019220
pages 899-914

EXPERIMENTAL STUDY OF ORGANIC RANKINE CYCLE SYSTEM USING SCROLL EXPANDER AND DIAPHRAGM PUMP AT DIFFERENT CONDENSING TEMPERATURES

Huan Xi
Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
Hong-Hu Zhang
Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China
Ya-Ling He
Key Laboratory of Thermo-fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China

ABSTRAKT

A small-scale RORC (organic Rankine cycle with a regenerator) system using a scroll expander and a diaphragm pump has been built. By using R123 as the working fluid, the expander, pump, and system performances are measured under different condensing temperatures. The maximum shaft power output of the expander obtained in this work is about 700 W. By increasing the shaft torque of the expander, the isentropic efficiency of the expander first increases and then decreases. The pressure ratio increases with increase of the shaft torque of the expander. The expander shows a highest shaft power output with the filling factor reaching 0.6—0.7. When Tc increases, both the pump work consumption and the pressure difference of the pump show an increasing trend, leading to an increase in the mass flow rate of the working fluid, which is the main reason for the increase of the shaft power output of the expander. The obtained minimum BWR is about 0.46, the maximum electricity efficiency of the pump is 34.2%. The maximum thermal and exergy efficiencies are 2.4% and 9.3%, respectively.


Articles with similar content:

Abstract of "THE PERFORMANCE OF THE REFRIGERANTS R-134a, R290, R404A, R-407c AND R-410A IN AIR CONDITIONERS AND REFRIGERATORS"
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Josua Petrus Meyer
DESIGN AND ANALYSIS OF A FAME-MLL VAPOR-COMPRESSION REFRIGERATION CYCLE COMPRESSOR
4th Thermal and Fluids Engineering Conference, Vol.30, 2019, issue
Chris McNamara, Thomas Gross, Ariel Gatti, Kevin R. Anderson
THE PERFORMANCE OF THE REFRIGERANTS R-134a, R290, R404A, R-407c AND R-410A IN AIR CONDITIONERS AND REFRIGERATORS
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Josua Petrus Meyer
EXPERIMENTAL STUDY ON PUMP APPLIED IN ORGANIC RANKINE CYCLE SYSTEM
Second Thermal and Fluids Engineering Conference, Vol.1, 2017, issue
Weicong Xu, Wen Su, Jianyuan Zhang, Shuai Deng, Li Zhao
ANALYSES OF ENTRANSY DISSIPATION RATIO AND ENTROPY GENERATION RATIO FOR GAS POWER CYCLES UNDER VARIOUS CONDITIONS: EDEG SOFTWARE
Heat Transfer Research, Vol.50, 2019, issue 1
Ankur Geete