Volumen 51, 2020 Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v41.i5.40
pages 531-558

Dimensionless Local and Average Boiling Heat Transfer Correlation for Saturated Liquids

Mihir Kumar Das
School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Odisha 752050, India
Satish C. Gupta
Department of Chemical Engineering, University of Roorkee, Roorkee - 247667 India
V. K. Agarwal
Chemical Engineering Department, Indian Institute of Technology Roorkee, Roorkee - 247667

ABSTRAKT

The present study is an experimental investigation on nucleate pool boiling of saturated liquids namely, distilled water, methanol, and iso-propanol over a plain copper heating tube at atmospheric and sub-atmospheric pressures. The study includes the effect of operating parameters, i.e., heat flux and pressure on the boiling heat transfer coefficient of saturated liquids on a copper heating tube. The boiling heat transfer coefficient is determined locally at the bottom, two sides and at the top position of the heating tube and a dimensionless equation of the form h*ψ/h*ψ,1= [(a+b cos ψ)/ (a+b cos ψ)1](ρ/ρ1)0.32 is established for prediction of the local boiling heat transfer coefficient at different pressures. Further, a dimensional equation, h = Cq0.7ρ0.32 , is established for determination of the average boiling heat transfer coefficient of saturated liquids on a plain copper heating tube. The dimensionless correlations of earlier investigators are tested with experimental data of the present investigation for the sake of comparison. Further, a dimensionless correlation of the form: Nu*B = Csf(Pe*B)0.7(Kp)0.7(Pr)−0.67 is proposed. The correlation is found to fit experimental data of the present investigation within a maximum error of ±6.