Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Porous Media
Impact-faktor: 1.49 5-jähriger Impact-Faktor: 1.159 SJR: 0.43 SNIP: 0.671 CiteScore™: 1.58

ISSN Druckformat: 1091-028X
ISSN Online: 1934-0508

Volumes:
Volumen 22, 2019 Volumen 21, 2018 Volumen 20, 2017 Volumen 19, 2016 Volumen 18, 2015 Volumen 17, 2014 Volumen 16, 2013 Volumen 15, 2012 Volumen 14, 2011 Volumen 13, 2010 Volumen 12, 2009 Volumen 11, 2008 Volumen 10, 2007 Volumen 9, 2006 Volumen 8, 2005 Volumen 7, 2004 Volumen 6, 2003 Volumen 5, 2002 Volumen 4, 2001 Volumen 3, 2000 Volumen 2, 1999 Volumen 1, 1998

Journal of Porous Media

DOI: 10.1615/JPorMedia.v16.i8.10
pages 683-694

ASSESSMENT OF X-RAY MICRO-CT MEASUREMENTS OF POROSITY AND SOLUTE CONCENTRATION DISTRIBUTIONS DURING DIFFUSION IN POROUS GEOLOGIC MEDIA

H. M. D. Agbogun
Department of Earth Sciences, University of New Brunswick; Laboratory for Threat Material Detection, Department of Mechanical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada E3B 5A3
Esam M. A. Hussein
Laboratory for Threat Material Detection, Department of Mechanical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada E3B 5A3
Tom A. Al
Department of Earth Sciences, University of Ottawa

ABSTRAKT

Using x-ray micro-computed tomography (micro-CT) for quantitative measurements in porous media is inherently challenged by uncertainties, which need to be identified and quantified to enable meaningful interpretation of measurements. For this purpose, we present results of experiments using micro-CT to measure the three-dimensional distribution of diffusion-accessible porosity and time-variant iodide tracer concentration within dolostone and sandstone samples. The precision, detection limits and spatial resolution of measurements were determined. Using a 0.6 M iodide tracer, the precision of attenuation coefficient measurement was approximately ±4%, in both the dolostone and sandstone samples. The precision for diffusion-accessible porosity and solute concentration measurements were ±7% and ±0.04 M, with detection limits of 20% and 0.12 M, respectively. The spatial resolution of measurement was 40 μm, representing the minimum size of features that can be distinctively resolved in a reconstructed image with 18.23 μm voxel size.


Articles with similar content:

IMAGE CORRELATION OF PARTICLE DISTRIBUTION BY DISCRETE WAVELET TRANSFORM OF CAPACITANCE CT IMAGES
Journal of Flow Visualization and Image Processing, Vol.9, 2002, issue 4
Mitsuaki Ochi, Kiyoshi Horii, Masahiro Takei, Yoshifuru Saito, Hui Li
AN EXPERIMENTAL STUDY OF THERMAL CONVECTION IN FLUID-SUPERPOSED POROUS LAYERS HEATED FROM BELOW
International Heat Transfer Conference 9, Vol.5, 1990, issue
Q. Tian, Vishwanath Prasad
MEASUREMENTS OF THE LOCAL RELATIVE VELOCITY AND THE PROFILE EFFECTS ON PREDICTION OF THE AREA-AVERAGED RELATIVE VELOCITY
Multiphase Science and Technology, Vol.25, 2013, issue 2-4
Xinquan Zhou, In Hun Kim, Benjamin Doup, Xiaodong Sun
MEASURING HOLD-UP AND CONVECTIVE TRANSPORT IN STRUCTURED PACKINGS FOR HEAT AND MASS TRANSFER USING X-RAY TOMOGRAPHY
International Heat Transfer Conference 13, Vol.0, 2006, issue
Bastian Mahr, Dieter Mewes
Regional Measurements of Surface Deviation Volume in Worn Polyethylene Joint Replacement Components
Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 1
Daniel Lorusso, David W. Holdsworth, Jennifer L. Au, Jaques S. Milner, Matthew G Teeter, Douglas D. R. Naudie