Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Critical Reviews™ in Biomedical Engineering
SJR: 0.26 SNIP: 0.375 CiteScore™: 1.4

ISSN Druckformat: 0278-940X
ISSN Online: 1943-619X

Volumes:
Volumen 48, 2020 Volumen 47, 2019 Volumen 46, 2018 Volumen 45, 2017 Volumen 44, 2016 Volumen 43, 2015 Volumen 42, 2014 Volumen 41, 2013 Volumen 40, 2012 Volumen 39, 2011 Volumen 38, 2010 Volumen 37, 2009 Volumen 36, 2008 Volumen 35, 2007 Volumen 34, 2006 Volumen 33, 2005 Volumen 32, 2004 Volumen 31, 2003 Volumen 30, 2002 Volumen 29, 2001 Volumen 28, 2000 Volumen 27, 1999 Volumen 26, 1998 Volumen 25, 1997 Volumen 24, 1996 Volumen 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.2018027320
pages 311-339

Diffusion Tensor Imaging of Tendons and Ligaments at Ultra-High Magnetic Fields

Martina Guidetti
Acoustics and Vibrations Laboratory, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL
Marco Andrea Zampini
Motion-Encoding MRI Laboratory, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL
Giulia Gandini
Acoustics and Vibrations Laboratory, Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL
Aman Gupta
Affiliated Engineering Laboratories, Inc., Edison, NJ
Weiguo Li
Research Resource Center, University of Illinois at Chicago, Chicago, IL
Richard L. Magin
Diagnostic Imaging System Group (DIS), Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, 851 South Morgan Street, Chicago, IL 60607, USA
Vincent M. Wang
Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA

ABSTRAKT

Injuries to tendons and ligaments are a common problem limiting daily activities and athletic participation across all age groups. Conventional magnetic resonance imaging (MRI) is reliable for detecting complete tears in tendons and ligaments, but it has difficulty identifying low-grade injuries due to poor contrast and low intensity signal. We describe recent MRI advances using ultra-high magnetic fields and very short time echoes which overcome many of the limitations of the low signal and the short T2 of connective tissues. Using diffusion and relaxometry measurements at 11.7 T, we measured the high field relaxation times, mean diffusivity, and the fractional anisotropy of rabbit semitendinosus tendons and medial collateral ligaments. We found that ultra-high field diffusion tensor imaging and tractography provide repeatable and quantitative maps of fiber organization, which could improve injury diagnosis and therapeutic treatments and assist in presurgical planning.


Articles with similar content:

Neuromuscular Stimulation for Motor Neuroprosthesis in Hemiplegia
Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.12, 2000, issue 1
Ronald Triolo, Kevin Kilgore, John Chae, David Yu
Magnetic Resonance of Brown Adipose Tissue: A Review of Current Techniques
Critical Reviews™ in Biomedical Engineering, Vol.43, 2015, issue 2-3
Houchun Harry Hu
Long-Term Results of Anterior Cruciate Ligament Reconstruction Using Semitendinosus and Gracilis Tendons with Kennedy Ligament Augmentation Device Compared with Patellar Tendon Autografts
Journal of Long-Term Effects of Medical Implants, Vol.10, 2000, issue 4
Yoshio Kumagae, Keishi Marumo, Takaaki Tanaka, Katsuyuki Fujii
Brain-Computer Interfaces for Neurorehabilitation
Critical Reviews™ in Biomedical Engineering, Vol.41, 2013, issue 3
C. Kesavadas, Joseph S. Paul, Ranganatha Sitaram, Sujesh Sreedharan
Unconventional Gradient Coil Designs in Magnetic Resonance Imaging
Critical Reviews™ in Biomedical Engineering, Vol.42, 2014, issue 6
Minhua Zhu, Ling Xia, Feng Liu