Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Critical Reviews™ in Biomedical Engineering
SJR: 0.207 SNIP: 0.376 CiteScore™: 0.79

ISSN Druckformat: 0278-940X
ISSN Online: 1943-619X

Volumes:
Volumen 47, 2019 Volumen 46, 2018 Volumen 45, 2017 Volumen 44, 2016 Volumen 43, 2015 Volumen 42, 2014 Volumen 41, 2013 Volumen 40, 2012 Volumen 39, 2011 Volumen 38, 2010 Volumen 37, 2009 Volumen 36, 2008 Volumen 35, 2007 Volumen 34, 2006 Volumen 33, 2005 Volumen 32, 2004 Volumen 31, 2003 Volumen 30, 2002 Volumen 29, 2001 Volumen 28, 2000 Volumen 27, 1999 Volumen 26, 1998 Volumen 25, 1997 Volumen 24, 1996 Volumen 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.v34.i3.10
pages 187-213

A Review of Coaxial-Based Interstitial Antennas for Hepatic Microwave Ablation

John M. Bertram
Department of Biomedical Engineering, University of Wisconsin, Madison, WI 53792 USA
Deshan Yang
Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI 53792 USA
Mark C. Converse
Department of Surgery, University of Wisconsin, Madison, WI 53792 USA
John G. Webster
Department of Biomedical Engineering, University of Wisconsin, Madison, WI 53792 USA
David M. Mahvi
Department of Surgery, University of Wisconsin, Madison, WI 53792 USA

ABSTRAKT

Although surgical resection remains the gold standard for treatment of liver cancer, there is a growing need for alternative therapies. Microwave ablation (MWA) is an experimental procedure that has shown great promise for the treatment of unresectable tumors and exhibits many advantages over other alternatives to resection, such as radiofrequency ablation and cryoablation. However, the antennas used to deliver microwave power largely govern the effectiveness of MWA. Research has focused on coaxial-based interstitial antennas that can be classified as one of three types (dipole, slot, or monopole). Choked versions of these antennas have also been developed, which can produce localized power deposition in tissue and are ideal for the treatment of deep-seated hepatic tumors.


Articles with similar content:

Biomedical Concerns in Wireless Communications
Critical Reviews™ in Biomedical Engineering, Vol.26, 1998, issue 1-2
Maria A. Stuchly
Laser-Induced Thermal Therapy for Tumor Ablation
Critical Reviews™ in Biomedical Engineering, Vol.38, 2010, issue 1
David Fuentes, R. Jason Stafford, Andrew A. Elliott, Kamran Ahrar, Jeffrey S. Weinberg
Polymer-Based Drug Delivery Systems for Cancer
Critical Reviews™ in Therapeutic Drug Carrier Systems, Vol.35, 2018, issue 6
Ru Wen, Ammad Ahmad Farooqi, Afoma C. Umeano, Pingping Chen
Technical Aspects of Electromagnetic Hyperthermia in Medicine
Critical Reviews™ in Biomedical Engineering, Vol.29, 2001, issue 1
E. A. Gel'vich, V. N. Mazokhin
Long-Acting Injectables: Current Perspectives and Future Promise
Critical Reviews™ in Therapeutic Drug Carrier Systems, Vol.36, 2019, issue 2
Komal Chaudhary, Mayur M. Patel, Priti J. Mehta