Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2013006564
pages 43-58

AIRSIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SINE WAVE OR SINE WAVE-SLIT FINS

Nae-Hyun Kim
Department of Mechanical Engineering, Incheon National University, 12-1 Songdo-Dong, Yeonsu-Gu Inchon, 22012, Korea
Baek Youn
Air Conditioner and Refrigerator Division, Samsung Electronics Co., Suwon, Korea

ABSTRAKT

The heat transfer and friction characteristics of heat exchangers having sine wave or sine wave-slit fins were experimentally investigated. Thirty-eight samples having different waffle heights (1.5 and 2.0 mm), fin pitches (1.3 to 1.7 mm), and tube rows (one to three) were tested. Results show that the sine wave-slit geometry provided 20% higher heat transfer coefficients and 44% higher friction factors than the sine wave geometry. The j/f ratios of the sine wave geometry, however, were higher than those of the sine wave-slit geometry. Within the present geometric variations, the effect of waffle height on the heat transfer coefficient was not prominent. The effect of fin pitch on j and f factor was also negligible for sine wave fin. For sine wave-slit fin, however, both j and f factors increased as fin pitch decreased. New correlations were developed based on the present data.


Articles with similar content:

AN EXPERIMENTAL INVESTIGATION OF THE AIR-SIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SLIT FINS
Journal of Enhanced Heat Transfer, Vol.22, 2015, issue 1
Honggi Cho, Nae-Hyun Kim
Effect of Fin Specification on Thermal Performance of Fin-Tube Heat Exchanger for Heat Pump under Frosting Condition
International Heat Transfer Conference 15, Vol.21, 2014, issue
Jeongkeun Kim, Keumnam Cho
HEAT TRANSFER AND FRICTION CHARACTERISTICS OF FIN-AND-TUBE HEAT EXCHANGERS
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Wei-Mon Yan, Pay-Jen Sheen
Steam Condensation on Horizontal Integral-Fin Tubes of Low Thermal Conductivity
Journal of Enhanced Heat Transfer, Vol.3, 1996, issue 1
M. Hassib Jaber, Ralph L. Webb
Heat transfer enhancement for finned-tube heat exchangers with vortex generators: experimental and numerical results
International Heat Transfer Conference 12, Vol.48, 2002, issue
Manohar S. Sohal, James E. O'Brien, Philip Carl Wallstedt, Thomas D. Foust