Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Enhanced Heat Transfer
Impact-faktor: 1.406 5-jähriger Impact-Faktor: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Druckformat: 1065-5131
ISSN Online: 1026-5511

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v10.i3.40
pages 287-300

The Effects of Gap Position in Discrete Ribs on Local Heat/Mass Transfer in a Square Duct

Hyung-Hee Cho
School of Mechanical Engineering, Yonsei University, Seoul 120 749, South Korea
Y. Y. Kim
Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Korea
Dong-Ho Rhee
Korea Aerospace Research Institute Daejeon, 305-333, Korea
Sei Young Lee
Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Korea
S. J. Wu
Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Korea
C. K. Choi
Department of Mechanical Engineering, Seoul National University, Seoul 120-749, Korea

ABSTRAKT

Local heat/mass transfer measurements are conducted to investigate the effects of rib arrangements and gap positions on the discrete rib. The combined effects of the gap flows of the discrete ribs and secondary flows are examined in order to promote uniformity of heat/mass transfer distributions, as well as to augment heat/mass transfer. A square channel with rectangular ribs is used for the stationary duct test. The rib-to-rib pitch to the rib height ratio is 8, and the rib attack angle is 60°. The gap width is the same as the rib width, and two gap positions, which are upstream and downstream gaps, are examined with parallel and cross rib arrangements. A naphthalene sublimation method is used to measure local heat/mass transfer coefficients. With the angled discrete ribs, the heat transfer on the surface is enhanced and the uniformity of the heat transfer coefficients is promoted because the gap flow promotes local turbulence and flow mixing near the ribbed surface, while the rib-induced secondary flow is maintained in a duct. The discrete rib arrangements with downstream gaps show better cooling performance than continuous rib or discrete rib arrangements with upstream gaps.


Articles with similar content:

Local heat/mass transfer characteristics in a square duct with various rib arrangements
International Heat Transfer Conference 12, Vol.47, 2002, issue
Y. Y. Kim, Chung Choi, Dong Ho Rhee, Sei Young Lee, Hyung-Hee Cho, S. J. Wu
Effects of Rib-Induced Secondary Flow on Heat Transfer Augmentation Inside a Circular Tube
Journal of Enhanced Heat Transfer, Vol.10, 2003, issue 1
Virgil Stoica, Akira Murata, Robert Kiml, Sadanari Mochizuki
Heat Transfer Enhancement by Rib-Induced Secondary Flow inside a Circular Tube
International Heat Transfer Conference 12, Vol.47, 2002, issue
Virgil Stoica, Akira Murata, Robert Kiml, Sadanari Mochizuki
EFFECTS OF GAPS BETWEEN THE SIDE-WALLS AND RIBS ON THE RIB-INDUCED FLOW STRUCTURE AND HEAT TRANSFER DISTRIBUTION INSIDE A HIGH ASPECT RATIO COOLING CHANNEL
Journal of Flow Visualization and Image Processing, Vol.9, 2002, issue 2&3
Akira Murata, Robert Kiml, Sadanari Mochizuki
Distributions of Local Heat Transfer Coefficient on Surfaces with Solid and Perforated Ribs
Journal of Enhanced Heat Transfer, Vol.5, 1998, issue 1
S. C. Lau, R. T. Kukreja