Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Enhanced Heat Transfer
Impact-faktor: 1.406 5-jähriger Impact-Faktor: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Druckformat: 1065-5131
ISSN Online: 1563-5074

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2011002711
pages 1-11

PERFORMANCE CHARACTERISTICS OF DEEP CORRUGATED TUBES WITH TWISTED-TAPE INSERTS

Ventsislav D. Zimparov
Gabrovo Technical University, 4 Hadji Dimitar Strasse, 5300 Gabrovo, Bulgaria
Valentin Metodiev Petkov
Gabrovo Technical University, 4, Hadji Dimitar, Str. 5300 Gabrovo, Bulgaria
Arthur E. Bergles
Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, New York; University of Maryland, College Park, Maryland; Massachusetts Institute of Technology, Cambridge, Massachusetts, USA

ABSTRAKT

Recent investigation of the performance characteristics of some passive compound heat transfer enhancement techniques revealed that the combination of corrugated tubes with twisted-tape inserts seems to be a very attractive enhancement technique for single-phase turbulent flow. This holds in the range of height-to-diameter ratios e/Di > 0.04 and small relative pitches of the twisted tape, H/Di. This paper presents the latest results of an experimental investigation of the friction factors and heat transfer coefficients (inside with water as working fluid and outside with condensing steam) of eight single-start, spirally corrugated tubes with geometrical parameters: 0.053 < e/Di < 0.089 and ridge pitch-to-height ratio 6.8 < p/e < 11.0 combined with twisted tapes with H/Di = 4.7, 5.7, and 7.6, in the range of Reynolds number, 3.5 × 103 < Re < 5.0 × 104. The increase of outside heat transfer coefficient E0 is presented as a function of geometrical parameters of the depth of the corrugated tube through the Weber number, We, and the relative pitch of the twisted tape H/Di. The effect of Reynolds number on E0 is discussed.


Articles with similar content:

Performance Characteristics of Some "Rough Surfaces" with Tube Inserts for Single-Phase Flow
Journal of Enhanced Heat Transfer, Vol.13, 2006, issue 2
Arthur E. Bergles, Plamen J. Penchev, Ventsislav D. Zimparov
Compound heat transfer enhancement by a combination of spirally corrugated tubes with a twisted tape
International Heat Transfer Conference 12, Vol.47, 2002, issue
Ventsislav D. Zimparov, Valentin Metodiev Petkov
ENHANCEMENT OF HEAT TRANSFER BY A COMBINATION OF A SINGLE START SPIRALLY CORRUGATED TUBES WITH A TWISTED TAPE
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Ventsislav D. Zimparov
Abstract of "ENHANCEMENT OF HEAT TRANSFER BY A COMBINATION OF A SINGLE START SPIRALLY CORRUGATED TUBES WITH A TWISTED TAPE"
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Ventsislav D. Zimparov
Compound Heat Transfer Enhancement - Performance Characteristics of Some "Rough Surfaces" with Twisted Tape Inserts
ICHMT DIGITAL LIBRARY ONLINE, Vol.2, 2004, issue
Plamen J. Penchev, Ventsislav D. Zimparov