Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Enhanced Heat Transfer
Impact-faktor: 0.562 5-jähriger Impact-Faktor: 0.605 SJR: 0.211 SNIP: 0.361 CiteScore™: 0.33

ISSN Druckformat: 1065-5131
ISSN Online: 1026-5511

Volumes:
Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v10.i4.70
pages 431-444

Effects of Rib Height on Heat Transfer Performance Inside a High Aspect Ratio Channel with Inclined Ribs

Robert Kiml
Tokyo University of Agriculture and Technology, Department of Mechanical Systems Engineering, Koganei-shi,Nakacho 2-24-16,Tokyo 184-8588, Japan
Sadanari Mochizuki
Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei-shi, Tokyo 184, JAPAN
Akira Murata
Department of Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan

ABSTRAKT

Heat transfer and pressure drop experiments were performed in a rectangular high aspect ratio channel (5:1, 45 ґ 9 mm) representing a turbine blade trailing edge cooling passage. The oblique ribs were attached to two opposing long side walls and were intended to function as secondary flow inducers as well as turbulators to improve the heat transfer of the both rib-roughened and rear (one of the short side walls) walls. The experiments were performed for three rib heights—h = 3 mm, h = 2 mm, and h = 1 mm (h-rib height)—for two rib arrangements, transverse (90°) and inclined (60°). It was verified that (1) the heat transfer enhancement on the rear wall was attributed to the rib-induced secondary flow, which carries the cold air from the passage core region toward the rear wall and enhances the heat transfer appreciably; and (2) heat transfer and pressure drop strongly deteriorate with a decreasing rib height because of the weakening of the rib-induced positive effects as a turbulence promoter and secondary flow inducer.


Articles with similar content:

LIQUID CRYSTAL VISUALIZATIONS AND MEASUREMENTS OF HEAT TRANSFER IN A SQUARE DUCT WITH DIFFERENT PITCHES OF VORTEX GENERATOR ARRAYS
Journal of Flow Visualization and Image Processing, Vol.5, 1998, issue 4
Tzi-Wei Tsai, Chung-Chu Chen, Tong-Miin Liou
HEAT TRANSFER ENHANCEMENT MECHANISM IN A RECTANGULAR PASSAGE WITH V- AND L-SHAPED RIBS
Journal of Flow Visualization and Image Processing, Vol.8, 2001, issue 1
Akira Murata, Robert Kiml, Sadanari Mochizuki
Local heat/mass transfer characteristics in a square duct with various rib arrangements
International Heat Transfer Conference 12, Vol.47, 2002, issue
Y. Y. Kim, Chung Choi, Dong Ho Rhee, Sei Young Lee, Hyung-Hee Cho, S. J. Wu
PIV MEASUREMENTS OF DUCT FLOW WITH A DETACHED TURBULATOR ARRAY
Journal of Flow Visualization and Image Processing, Vol.8, 2001, issue 2-3
Shun-Nan Liou, K. H. Chang, Tong-Miin Liou
VISUALIZATION OF END WALL FLOW IN A LARGE DEFLECTION TURBINE ROTOR CASCADE: EFFECT OF TIP CLEARANCE AND INCIDENCE ANGLE
Journal of Flow Visualization and Image Processing, Vol.8, 2001, issue 4
Mukka Govardhan, R. M. Wankhade, B.H.Lakshmana Gowda