Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Enhanced Heat Transfer
Impact-faktor: 1.406 5-jähriger Impact-Faktor: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Druckformat: 1065-5131
ISSN Online: 1563-5074

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v24.i1-6.330
pages 609-626

A REVIEW ON HEAT TRANSFER AND PRESSURE DROP DURING EVAPORATION AND CONDENSATION OF R22 INSIDE 9.52-MM O.D. MICROFIN TUBES OF DIFFERENT GEOMETRIES

Adriano Muzzio
Dipartimento di Energetica - Politecnico di Milano, Milan, Italy
Alfonso Niro
Department of Energy, Politecnico di Milano, Via Lambruschini 4, Milano IT−20156, Italy
S. Arosio
Dipartimento di Ingegneria Energetica, Universita di Genova, Politecnico di Milano piazza Leonardo da Vinci 32, 20133 Milano, Italy

ABSTRAKT

Saturated flow boiling and convective condensation experiments for oil-free Refriger-ant-22 have been carried out with a microfin tube with a new cross-section profile, as well as with two traditional microfin tubes and with a smooth one. All tubes have the same outer diameter. Data are for mass fluxes ranging from about 90 to 400 kg/m2·s. In boiling tests, the nominal saturation temperature is 5°C, with inlet quality varying from 0.2 to 0.6 and the quality variation along the test section ranging from 0.1 to 0.5. In condensation, results are for saturation temperature equal to 35°C, with inlet and outlet qualities of 0.8 and 0.2, respectively. The new microfin tube shows the best thermal performances among the microfin tubes tested, especially in evaporation. For this case, the enhancement factor comes up to 4. Experimental results for microfin tubes are compared with predictions of a correlation scheme recently proposed; these predictions correlate well only with data for the microfin tube with a geometry much similar to one accounted by the scheme.


Articles with similar content:

Heat Transfer and Pressure Drop During Evaporation and Condensation of R22 inside 9.52-mm O.D. Microfin Tubes of Different Geometries
Journal of Enhanced Heat Transfer, Vol.5, 1998, issue 1
Alfonso Niro, S. Arosio, Adriano Muzzio
Experimental heat transfer coefficient and pressure drop during condensation of R22 and R407C inside a horizontal microfin tube
International Heat Transfer Conference 12, Vol.48, 2002, issue
Luca Doretti, Luisa Rossetto, Claudio Zilio, Giuseppe Censi, Giovanni Antonio Longo, Alberto Cavallini, Davide Del Col
HEAT TRANSFER AND PRESSURE DROP DURING EVAPORATION AND CONDENSATION OF R134a INSIDE TWO MICROFIN TUBES OF NEW DESIGN
International Heat Transfer Conference 13, Vol.0, 2006, issue
Alfonso Niro, Andrea Lucchini, Luigi Pietro Maria Colombo, Adriano Muzzio
HEAT TRANSFER AND PRESSURE DROP DURING CONDENSATION OF R-410A IN ALUMINUM EXTRUDED ENHANCED TUBES
Heat Transfer Research, Vol.51, 2020, issue 10
Nae-Hyun Kim
CONDENSATION HEAT TRANSFER CHARACTERISTICS AND PRESSURE DROP OF R410A AND R22 IN MULTIPORT RECTANGULAR CHANNEL
Second Thermal and Fluids Engineering Conference, Vol.45, 2017, issue
Jong-Taek Oh, Pham Quang Vu, Nguyen Ba Chien, Kwang-Il Choi