Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Enhanced Heat Transfer
Impact-faktor: 1.406 5-jähriger Impact-Faktor: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Druckformat: 1065-5131
ISSN Online: 1563-5074

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v24.i1-6.60
pages 123-140

HEAT TRANSFER IN SQUARE CHANNELS WITH WEDGE-SHAPED AND DELTA-SHAPED TURBULENCE PROMOTERS

Je-Chin Han
Turbine Heat Transfer Laboratory, Department of Mechanical Engineering, Texas A&M University College Sation, TX 77843-3123, USA
J. Joy Huang
Department of Mechanical Engineering, Texas A & M University, College Station, Texas 77843-3123
Ching-Pang Lee
General Electric Company, Cincinnati, Ohio 45215, U.S.A.

ABSTRAKT

The effect of rib configuration on local heat transfer coefficients and pressure drop in a square channel with two opposite in-line ribbed walls was investigated at Reynolds numbers from 15,000 to 80,000. Two types of rib configurations were studied. The first group is a wedge-shaped rib with the rib height-to-hydraulic diameter ratio of 0.125 and the rib pitch-to-height ratio of 5 or 10. Both full length and broken ribs are studied. The second group is a delta-shaped rib with the rib height-to-hydraulic diameter ratio of 0.125 and the rib pitch-to-height ratio of 5. Both aligned and offset arrangements are studied for a forward and backward direction relative to the mainstream flow. Results show that, for the delta-shaped rib, the backward flow direction has higher heat transfer than the forward flow direction, and the aligned arrangement is better than the offset arrangement. The broken configuration for the wedge-shaped rib performs better than the full length one. In general, the delta-shaped rib performs better than the wedge-shaped rib. The backward delta-shaped aligned rib configuration produces the highest heat transfer augmentation (3-4 times), while the backward delta-shaped offset rib creates the smallest pressure drop penalty (5-6 times). Results also show that the surface heat flux ratio has significant effect on the smooth-side heat transfer augmentation, while the effect on the ribbed-side is relatively small.


Articles with similar content:

Augmented Heat Transfer in Square Channels with Wedge-Shaped and Delta-Shaped Turbulence Promoters
Journal of Enhanced Heat Transfer, Vol.1, 1994, issue 1
Je-Chin Han, J. Joy Huang, Ching-Pang Lee
A Louver Cooling Scheme for Gas Turbines Multiple Rows
ICHMT DIGITAL LIBRARY ONLINE, Vol.10, 2006, issue
Ibrahim Hassan, T. Lucas, X.-Z. Zhang
An Experimental Study of Heat Transfer in the Turn Region of a U-Bend channel with Various Ribs
International Heat Transfer Conference 15, Vol.23, 2014, issue
Lei Wang, Bengt Sunden, Chenglong Wang
Abstract of "HEAT TRANSFER IN ROTATING NARROW RECTANGULAR PIN-FIN DUCTS"
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Arthur E. Bergles, Fred T. Willett
HEAT TRANSFER IN ROTATING NARROW RECTANGULAR PIN-FIN DUCTS
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Arthur E. Bergles, Fred T. Willett