pages 255-270

SIMULATIONS AND MEASUREMENTS OF THE PRE-ARCING TIMES IN HBC FUSES UNDER TYPICAL ELECTRIC FAULTS

S. Memiaghe
Laboratoire Arc Electrique et Plasmas Thermiques CNRS FRE 3120, Phys. Bât. 5 - Université Blaise Pascal, Aubière Cedex, France; and P.R.E.S. Clermont Université, Clermont-Ferrand Cedex 1, France
W. Bussiere
LAEPT CNRS UMR 6069 - Phys. Bat. 5 - Université Blaise Pascal - 24, Avenue des Landais - 63177 Aubiere Cedex - France; and P.R.E.S.Clermont Université, 9 rue Kessler B.P. 10448 63012 Clermont-Ferrand Cedex 1, France
D. Rochette
Laboratoire Arc Electrique et Plasmas Thermiques CNRS FRE 3120, Phys. Bât. 5 - Université Blaise Pascal, Aubière Cedex, France; and P.R.E.S. Clermont Université, Clermont-Ferrand Cedex 1, France
R. Touzani
Laboratoire de Mathématiques CNRS UMR 6620, Campus Universitaire des Cézeaux, 24 Avenue des Landais, F63177 Aubière Cedex, France; P.R.E.S.Clermont Université, 9 rue Kessler B.P. 10448 63012 Clermont-Ferrand Cedex 1
P. Andre
Laboratoire Arc Electrique et Plasmas Thermiques CNRS FRE 3120, Phys. Bât. 5 - Université Blaise Pascal, Aubière Cedex, France; and P.R.E.S. Clermont Université, Clermont-Ferrand Cedex 1, France

ABSTRAKT

This work deals with the comparison between calculations and measurements of pre-arcing times in High Breaking Capacity fuses under typical fault current conditions. This paper also describes the temperature evolution and the Joule energy dissipated in a fuse element during the pre-arcing time. By varying typical electrical parameters, namely the closing angle and the power factor, we show that various prospective currents such as those observed in industrial case can be fairly simulated. The pre-arcing time and then the clearing of the fault current are shown to be deeply dependent on these electrical characteristics. We exhibit simulated results of prospective current and supply voltage waves for given closing angles under two typical power factors which are compared with the experimental ones. A comparison between simulated pre-arcing times with experimental ones shows some discrepancies and a discussion on the numerical assumptions is made.


Articles with similar content:

COLD ELECTRODE EROSION MODEL FOR PULSED ARCS APPLIED TO THE ELECTRICAL DISCHARGE MACHINING PROCESS
Progress in Plasma Processing of Materials, 2003, Vol.0, 2003, issue
A. M. Essiptchouk, L. I. Sharakhovsky, A. Marotta
COLD ELECTRODE EROSION MODEL FOR PULSED ARCS APPLIED TO THE ELECTRICAL DISCHARGE MACHINING PROCESS
High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes, Vol.7, 2003, issue 3
A. M. Essiptchouk, L. I. Sharakhovsky, A. Marotta
ANALYTICAL AND NUMERICAL INVESTIGATION OF U-TUBE HEAT EXCHANGERS
Transport Phenomena in Thermal Engineering. Volume 2, Vol.0, 1993, issue
Gian Luca Morini, Paolo Tartarini, E. Lorenzini, Marco Spiga
DYNAMIC AUTODYNE AND MODULATION CHARACTERISTICS OF MICROWAVE OSCILLATORS
Telecommunications and Radio Engineering, Vol.72, 2013, issue 10
K. A. Ignatkov, V. Ya. Noskov
ELECTRICALLY-CONTROLLED NEAR-FIELD RADIATIVE THERMAL MODULATOR
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2016, issue
Liping Wang, Yue Yang