Plasma Medicine

DOI: 10.1615/PlasmaMed.2016016815
pages 125-134

Plasma-Tissue Interactions in Argon Plasma Coagulation: Effects of Power and Tissue Resistance

Eda Gjika
Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, George Washington University, Washington, DC, USA
David Scott
Department of Mechanical and Aerospace Engineering, School of Engineering and Applied Science, George Washington University, Washington, DC, USA
Alexey Shashurin
The George Washington University; School of Aeronautics and Astronautics, Purdue University, West Lafayette, IN, USA
Taisen Zhuang
US Medical Innovations (USMI), LLC Corporate Headquarters, Takoma Park, MD, USA
Jerome Canady
Jerome Canady Research Institute for Advanced Biological and Technological Sciences, US Medical innovation LLC, Takoma Park, MD, USA
Michael Keidar
Department of Mechanical and Aerospace Engineering, The George Washington University, Science and Engineering Hall, 800 22nd Street, NW, Room 3550, Washington, DC 20052, USA

ABSTRAKT

The coagulation properties of the argon plasma coagulation (APC) technique present tremendous potential for a wide range of endoscopic applications. Although several studies have explored the endoscopic application of this technique, there has been no previous research about the relevant argon plasma properties during coagulation. We have investigated the role of power in the interactions between plasma and biological tissue, and have reported on the dielectric properties of the APC treated samples. The data revealed that at a resistance of 1 kΩ, the applied power was within 10% to 15% of the power setting, and the average resistance of the animal samples was between 0.8 and 3.7 kΩ. The data also suggested that the amount of power applied could be adjusted according to the expected tissue resistance range. Additionally, it was determined that the burned surface caused by the APC treatment was on average two to three times less conductive than the untreated surface. The data also revealed that 60%−80% of the power produced by the electrosurgical generator was delivered into the biological tissue, and the plasma channel consumed the remaining 20%−40%. This study establishes a guide for the investigation of optimal argon thermal plasma properties for biological tissue application.


Articles with similar content:

LIBS ANALYSIS OF PHOTOVOLTAIC MATERIAL INCLUDING WAFER AND RAW MATERIAL
High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes, Vol.10, 2006, issue 4
Jacques Amouroux, A. Soric, N. Leone, P. Adam, Daniel Morvan
Plasma Acid Production in a Gliding Arc Plasmatron
Plasma Medicine, Vol.2, 2012, issue 4
Ryan D. Robinson, Alexander A. Fridman, Alexander Rabinovich, Kirill Gutsol
Action of an Argon/Water Vapor Plasma Jet in the Sterilization of Silicone Contaminated with Candida albicans
Plasma Medicine, Vol.7, 2017, issue 3
Jhonatan Steffens Brandao Lima, Homero Santiago Maciel, Fernanda Ramos Figueira, Anelise C.O.C. Doria, Ligia Satiko Simomura, Sonia Khouri, Guilherme Torello Cassiano Redi, Rodrigo Savio Pessoa
Experimental Study of Atmospheric Pressure Argon Plasma Jet−Induced Strand Breakage in Large DNA Molecules
Plasma Medicine, Vol.7, 2017, issue 1
Himal Shrestha, Aman Maharjan, Sandeep Adhikari, Gyanu R. Pandey, Deepak P. Subedi, Rajendra Shrestha
Total Voltage Drops in Electrode Fall Regions of High Pressure Arcs between Electrodes of Cu-W, Cu, Fe, Ti, C and W in Current Range up to 20000A
Progress in Plasma Processing of Materials, 1997, Vol.1, 1997, issue
Y. Kito, Y. Yokomizu, R. Henmi, T. Matsumura