Volumen 27, 2017 Volumen 26, 2016 Volumen 25, 2015 Volumen 24, 2014 Volumen 23, 2013 Volumen 22, 2012 Volumen 21, 2011 Volumen 20, 2010 Volumen 19, 2009 Volumen 18, 2008 Volumen 17, 2007 Volumen 16, 2006 Volumen 15, 2005 Volumen 14, 2004 Volumen 13, 2003 Volumen 12, 2002 Volumen 11, 2001 Volumen 10, 2000 Volumen 9, 1999 Volumen 8, 1998 Volumen 7, 1997 Volumen 6, 1996 Volumen 5, 1995 Volumen 4, 1994 Volumen 3, 1993 Volumen 2, 1992 Volumen 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v14.i3.40
24 pages

DEVELOPMENT OF AN AIR-BLAST ATOMIZER FOR INDEPENDENT CONTROL OF DROPLET SIZE AND SPRAY DENSITY

H. L. Clack
Department of Mechanical Engineering, University of California, Berkeley, Berkeley, California, USA
C. P. Koshland
School of Public Health, University of California, Berkeley, Berkeley, California, USA
D. Lucas
Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, California, USA
R. F. Sawyer
Department of Mechanical Engineering, University of California, Berkeley, Berkeley, California, USA

ABSTRAKT

The atomizer described is a novel twin-fluid design that allows independent control of mean droplet size and mean spray density. Designed to handle unpressurized fluids at low flow rates, the prefilming double-annular air-blast atomizer (PFDAAA) distributes fuel in a liquid film over a hollow, tapered cylindrical centerbody. Two independently controlled atomizing gas streams shear the inner and outer surfaces of the cylindrical fluid film at the injector tip, resulting in continuously variable atomization. Data taken during a series of cold-flow experiments include both mean droplet size and spray density measures. The data demonstrate that controlling the relative flow rates of the two atomizing gas streams produces droplet dispersions whose mean droplet size and spray density vary independently of each other. Measured values of Sauter mean diameter (SMD) for isopropyl alcohol sprays range from 250 to 3100 μm, and values of normalized interdroplet spacing range from 0.8 to 3.6 mean droplet diameters. When presented collectively, the mean droplet size and spray density data form a performance map indicating the operating range of the PFDAAA for the conditions tested. Parametrically variable sprays such as those generated by the PFDAAA constitute a previously unavailable experimental platform for spray combustion research. Investigations using laser diagnostics to probe a controlled, variable spray could provide insights into the physicochemical processes within a spray that ultimately affect combustion efficiency and pollutant formation.