Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Atomization and Sprays
Impact-faktor: 1.262 5-jähriger Impact-Faktor: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN Druckformat: 1044-5110
ISSN Online: 1936-2684

Volumes:
Volumen 29, 2019 Volumen 28, 2018 Volumen 27, 2017 Volumen 26, 2016 Volumen 25, 2015 Volumen 24, 2014 Volumen 23, 2013 Volumen 22, 2012 Volumen 21, 2011 Volumen 20, 2010 Volumen 19, 2009 Volumen 18, 2008 Volumen 17, 2007 Volumen 16, 2006 Volumen 15, 2005 Volumen 14, 2004 Volumen 13, 2003 Volumen 12, 2002 Volumen 11, 2001 Volumen 10, 2000 Volumen 9, 1999 Volumen 8, 1998 Volumen 7, 1997 Volumen 6, 1996 Volumen 5, 1995 Volumen 4, 1994 Volumen 3, 1993 Volumen 2, 1992 Volumen 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v10.i2.50
19 pages

CHARACTERIZATION OF PROTOTYPE HIGH-PRESSURE SWIRL INJECTOR NOZZLES, PART II: CFD EVALUATION OF INTERNAL FLOW

Changsoo Jang
Department of Mechanical Engineering, KAIST, Taejon, Korea
Choongsik Bae
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 373-1, Gusong-dong, Yuseong-gu, Daejon, 305-701, Republic of Korea
Sangmin Choi
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Yusong-gu, Taejon, Korea

ABSTRAKT

Static flow rate and initial cone angle of high-pressure swirl injector nozzles were characterized through measurements and computations as a preliminary optimization process of nozzle design. Prototype injectors were fabricated by modifying commercial multipoint injection (MPI) nozzles. Measurements of static flow rate were compared with the computations, and the agreements were satisfactory in values and tendencies with respect to the nozzle geometry and the needle lift. Initial cone angle was calculated and compared with measurements by the direct photographic imaging method. It could be predicted satisfactorily by introducing an adequate correction factor. Considering these cross-checking for a validation of the computational model, a parametric study was carried out to predict the flow rate and the initial cone angle with respect to selected design parameters.


Articles with similar content:

EXPERIMENTAL AND COMPUTATIONAL STUDY OF THE INFLUENCE OF PARTIAL NEEDLE LIFT ON NOZZLE FLOWIN DIESEL FUEL INJECTORS
Atomization and Sprays, Vol.22, 2012, issue 8
Jaime Gimeno, Raul Payri, Alejandro H. Plazas, O. Venegas
Time Dividing Analysis of Intermittent Fuel Spray Flows Measured by PDA
International Journal of Fluid Mechanics Research, Vol.24, 1997, issue 4-6
Tsuneaki Ishima, W.-Q. Long, T. Obokata
LINKING NOZZLE FLOW WITH SPRAY CHARACTERISTICS IN A DIESEL FUEL INJECTION SYSTEM
Atomization and Sprays, Vol.8, 1998, issue 3
Manolis Gavaises, C. Arcoumanis
BOUNDARY-LAYER CHARACTERISTICS OF A SWIRL ATOMIZER
Atomization and Sprays, Vol.2, 1992, issue 3
M. I. G. Bloor, M. Ledoux, Christophe Dumouchel, N. Dombrowski, Derek B. Ingham
THE EFFECT OF COLD AIR JET INJECTION UPON THE FILM COOLING EFFECTIVENESS OF COMBUSTION CHAMBER WALLS FOR DIFFERENT INJECTION GEOMETRIES
International Heat Transfer Conference 7, Vol.6, 1982, issue
R. Best