Abo Bibliothek: Guest
THMT-15. Proceedings of the Eighth International Symposium On Turbulence Heat and Mass Transfer
September, 15-18, 2015, Sarajevo, Bosnia and Herzegovina

DOI: 10.1615/ICHMT.2015.THMT-15


ISBN Print: 978-1-56700-427-4

ISBN CD: 978-1-56700-428-8

Numerical study of NOx reduction by reburning mechanically-activated micronized coal in a full-scale tangentially-fired boiler

pages 779-782
DOI: 10.1615/ICHMT.2015.THMT-15.1750
Get accessGet access

ABSTRAKT

The paper presents some results of numerical simulation of the effects of reburning of mechanicallyactivated micronized coal on NOx reduction in a tangentially fired boiler of 500 t/h steam production. The conventional RANS approach was used to compute two-phase (reactive dispersed particles in gaseous medium) multi-component system, with some modifications of models of particle heat transfer and their reactions. The comprehensive model was earlier verified in simulation of an 5 MW experimental combustor as well as in a full-scale real boiler. The comparison with the standard firing with pulverized coal showed that reburning of non-activated fine coal leads to a NOx reduction by about 20%, but increases the unburnt carbon residual by 23%. However, reburning of mechanically-activated coal of the same granulation reduces NOx by 30% and also diminishes the unburnt residual by 35%, demonstrating that reburning in general, but especially of activated micronized coal, is a feasible option for achieving significant reduction in NOx emission.

Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen Preise und Aborichtlinien Begell House Kontakt Language English 中文 Русский Português German French Spain