ABSTRACT

Limb salvage surgery and reconstruction of bone defects is challenging in orthopaedic oncology. Allogenic and autologous bone grafting are well-recognized methods for bone reconstruction. Custom-made and modular, cemented and cementless, mega-prostheses provide the modular options needed intraoperatively to bridge variable bone defects. However, these megaprostheses have worse long-term results compared to conventional total joint replacements. Mechanical failure, aseptic loosening, infection, dislocation, skin necrosis, extensor mechanism ruptures and periprosthetic fractures are acknowledged complications of orthopaedic oncology procedures. These complications are due to the large defects that need to be bridged with a more difficult fixation in the diaphysis of the native bone, the more complex restoration of joint biomechanics, the extensive soft-tissue resection, the lengthy surgical operations, and the need for chemotherapy and radiation therapy. Because of the difficulties and the high rate of complications associated with the implantation of such highly modular systems, the treatment of patients with malignant bone tumors should only be carried out in specialized centers.


Articles with similar content:

Tribological Study of Joint Pathology
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Michael J. Furey, Hugo P. Veit, La Shaun J. Berrien
SEPSIS SECONDARY TO DELAYED PRESENTATION OF NECROTISING FASCIITIS OF THE THIGH—PRESENTATION OF TWO CASES WITH A POOR OUTCOME
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 4
Anastasios Tsiotsias, Athanasios Papanikolaou, George Zouboulis, Stylianos Pernientakis, Theodore Balfousias, Alexandros P. Apostolopoulos, Efthymios Karadimas
Glass Ionomer Cements: A Review of Composition, Chemistry, and Biocompatibility as a Dental and Medical Implant Material
Journal of Long-Term Effects of Medical Implants, Vol.15, 2005, issue 6
David Gore, James E. Haubenreich, Robert E. Kovarik
Severe Metallosis Following Polyethylene Dislocation in a Mobile-Bearing Medial Unicompartmental Knee Replacement
Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 2-3
Ilias Katsougrakis, Rafik Fanous, Enrique Saavedra, Andrew Harrison, Alexandros P. Apostolopoulos
Rationale and Options for Choosing an Optimal Closure Technique for Primary Midsagittal Osteochondrotomy of the Sternum. Part 3: Technical Decision Making Based on the Practice of Patient- Appropriate Medicine
Critical Reviews™ in Biomedical Engineering, Vol.47, 2019, issue 1
Harjeet Singh Gandhi