Design Optimization of Skeletal Hip Implant Cross- Sections Using Finite-Element Analysis

Volumen 19, Edición 4, 2009, pp. 271-278
DOI: 10.1615/JLongTermEffMedImplants.v19.i4.40
Get accessGet access

SINOPSIS

The major causes for revision surgery after total hip arthroplasty are aseptic loosening, dislocation, wear, design factors, stress shielding on the bone, and mechanical and biological factors. A material with toughness and high wear properties is essential for a good hip implant because these implants fail due to design. Stress shielding is found to be the major cause for the failure of hip implants, and can lead to the implant needing to be replaced or revised, which is painful for the patient and costly for the health care industry. The hip stem designs developed by various manufacturers are solid stems with indentations; stems with collars; collarless, tapered stems; and teardrop-shaped, polished stems without indentations. They are found to have a greater rigidity, and therefore they transfer less load proximally, which results in high proximal stress shielding of the proximal femur. A stem of low stiffness alone would not suffice in achieving a reduced or optimal stress shielding. The existing design proposals to minimize the effect of stress shielding are focused on the use of lightweight materials, composite materials, circular and longitudinal hole patterns, and different hollow-bore depths. A skeletal hip implant with varying cross-sections was designed and finite-element analysis was performed. The skeletal hip implant with a hexagonal cross-section was optimized based on the mass of the implant and the load-bearing capacity. This lightweight, novel design ameliorates implant fixation, minimizes stress shielding, enhances the longevity of the implant, and offers better mobility to the patient.

CITADO POR
  1. LIU GUANG-YAO, JIN YAN, LI PENG, Investigation of creep mechanical characteristics of femoral prostheses by simulated hip replacement, Experimental and Therapeutic Medicine, 5, 4, 2013. Crossref

  2. Piao Chengdong, Wu Dankai, Luo Min, Ma Hongshun, Stress shielding effects of two prosthetic groups after total hip joint simulation replacement, Journal of Orthopaedic Surgery and Research, 9, 1, 2014. Crossref

Próximos Artículos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones Precios y Políticas de Suscripcione Begell House Contáctenos Language English 中文 Русский Português German French Spain