Design Optimization of Skeletal Hip Implant Cross- Sections Using Finite-Element Analysis

Pearline Beulah
Biomedical Engineering Division, School of Biosciences and Technology, Vellore Institute of Technology (VIT) University, Vellore, India
Sudesh Sivarasu
University of Cape Town
Lazar Mathew
Centre for Biomedical Research, Vellore Institute of Technology (VIT) University, Vellore, India

SINOPSIS

The major causes for revision surgery after total hip arthroplasty are aseptic loosening, dislocation, wear, design factors, stress shielding on the bone, and mechanical and biological factors. A material with toughness and high wear properties is essential for a good hip implant because these implants fail due to design. Stress shielding is found to be the major cause for the failure of hip implants, and can lead to the implant needing to be replaced or revised, which is painful for the patient and costly for the health care industry. The hip stem designs developed by various manufacturers are solid stems with indentations; stems with collars; collarless, tapered stems; and teardrop-shaped, polished stems without indentations. They are found to have a greater rigidity, and therefore they transfer less load proximally, which results in high proximal stress shielding of the proximal femur. A stem of low stiffness alone would not suffice in achieving a reduced or optimal stress shielding. The existing design proposals to minimize the effect of stress shielding are focused on the use of lightweight materials, composite materials, circular and longitudinal hole patterns, and different hollow-bore depths. A skeletal hip implant with varying cross-sections was designed and finite-element analysis was performed. The skeletal hip implant with a hexagonal cross-section was optimized based on the mass of the implant and the load-bearing capacity. This lightweight, novel design ameliorates implant fixation, minimizes stress shielding, enhances the longevity of the implant, and offers better mobility to the patient.


Articles with similar content:

Improved Orthopaedic Bone Cement Formulations Based on Rubber Toughening
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 3&4
Jimmy W. Mays, Aaron D. Puckett, Lujia Bu, Brad Roberts
A Long Term Histological Analysis of Effect of Interposed Hydroxyapatite between Bone and Bone Cement in THA and TKA
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 2
Hironobu Oonishi
The Effect of Screw Insertion Site and Unused Drill Holes on Stability and Mode of Failure After Fixation of Basicervical Femoral Neck Fracture
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Ronald Goulet, Brent Norris, Paul Stafford
Bioceramics in Ossicular Replacement Prostheses: A Review
Journal of Long-Term Effects of Medical Implants, Vol.21, 2011, issue 2
Plawut Wongwiwat, Apichart Boonma, Yuan-Shin Lee, Roger J. Narayan
A New Design for Maximum Conformity of Total Knee Prosthesis to Femur and Tibia
Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 4
Ismail Hakki Korkmaz, Ömer S. Yildirim, İrfan Kaymaz