Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Heat Transfer Research
Factor de Impacto: 0.404 Factor de Impacto de 5 años: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN En Línea: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v39.i7.10
pages 559-570

Numerical Simulation of the Turbine Gas Meter Behavior in the Pulsating Flow

Jurij Tonkonogij
Lithuanian Energy Institute, Heat Equipment Research and Testing Laboratory, Breslaujos 3, LT-44403 Kaunas-35, Lithuania
Antanas Pedisius
Lithuanian Energy Institute, Siluminø árenginiø tyrimo ir bandymø laboratorija, Breslaujos str. 3, LT-44403 Kaunas, Lithuania

SINOPSIS

The facility for investigation of transient processes in turbine gas meters has been developed. The facility ensures instant switching of the turbine meter under test from one channel to another channel with different flow rate and measuring the meter response. The obtained results have been used for evaluating and predicting the meter dynamic errors at flow pulsation of any law. For this purpose, original combined computational-experimental method has been developed. The meter response and dynamic error have been evaluated as a function of frequency, amplitude, law of flow pulsation, and meter time constant of inertia.


Articles with similar content:

Enhanced Cardiac Thermal Dilution Analysis for Cardiac Output, Volumes, Stroke Volumes, and Regurgitation Rates — Sensitivity Analysis Using Digital Simulation
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Bruce C. Taylor, Francis M. Donovan, Jr.
FLAME PROPAGATION IN A CLOSED TUBE
International Heat Transfer Conference 8, Vol.2, 1986, issue
J.F. Lafortune, K.N. Tennankore
3D-MODEL BASED APPROACH FOR ESTIMATING MAXIMUM DISTANCE OF UAV VISUAL DETECTION
Telecommunications and Radio Engineering, Vol.77, 2018, issue 20
K. Abramov, I. Kaluzhynov, V. V. Lukin, S. K. Abramov, V. V. Abramova
Statistical Errors of Ranging in the Spectral Interferometry Technique
Telecommunications and Radio Engineering, Vol.55, 2001, issue 10-11
V. V. Kulik, A. A. Mogyla
The wetted area fraction of dropwise condensation with inert gases and drop drainage
International Heat Transfer Conference 12, Vol.50, 2002, issue
Cees W. M. van der Geld, F.L.A. Ganzevles