Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Journal of Porous Media
Factor de Impacto: 1.49 Factor de Impacto de 5 años: 1.159 SJR: 0.43 SNIP: 0.671 CiteScore™: 1.58

ISSN Imprimir: 1091-028X
ISSN En Línea: 1934-0508

Volumes:
Volumen 22, 2019 Volumen 21, 2018 Volumen 20, 2017 Volumen 19, 2016 Volumen 18, 2015 Volumen 17, 2014 Volumen 16, 2013 Volumen 15, 2012 Volumen 14, 2011 Volumen 13, 2010 Volumen 12, 2009 Volumen 11, 2008 Volumen 10, 2007 Volumen 9, 2006 Volumen 8, 2005 Volumen 7, 2004 Volumen 6, 2003 Volumen 5, 2002 Volumen 4, 2001 Volumen 3, 2000 Volumen 2, 1999 Volumen 1, 1998

Journal of Porous Media

DOI: 10.1615/JPorMedia.v14.i9.50
pages 805-814

A STUDY OF HEAT TRANSFER AND PRESSURE DROP DURING CONDENSATION AND EVAPORATION PROCESSES IN POROUS MEDIA, USING EXPERIMENTAL WORK AND DIMENSIONAL ANALYSIS: A CASE STUDY OF CARBON DIOXIDE (CO2)

Mohammad Tarawneh
The Hashemite University, Zarqa 13115 Jordan
A. Alshqirate
Al-Shoubak University College, Al-Balqa' Applied University, Al-Salt, Jordan
Mahmoud Ahmad Hammad
University of Jordan

SINOPSIS

This work presents experimental and analytical studies of convection change phase heat transfer coefficient and pressure drop during flow inside tubes filled with porous media (sand). Condensation and evaporation processes were considered. Carbon dioxide was used as a flowing fluid over a wide range of inlet pressures, porosities, and mass flow rates. The pressure drop was found to be significantly reasonable in condensation and negligible for evaporation processes. The experimental results of the convective heat transfer coefficient and pressure drop during these flows were obtained, listed as experimental data, and used to develop empirical correlations using the dimensional analysis method. The analytical data produced from developed correlations were listed. Comparison between experimental results and those obtained analytically proved to be compatible with an average standard deviation (ASD) of 5.97% for pressure drop, while for the convective heat transfer coefficient during condensation process the ASD was 7.35%, and for the convective heat transfer coefficient during evaporation processes the ASD was 4.6%.


Articles with similar content:

EXPERIMENTAL INVESTIGATION OF TWO-PHASE FLOW BOILING INSIDE POROUS MEDIA
International Heat Transfer Conference 16, Vol.4, 2018, issue
Benjamin Dietrich, Thomas Wetzel, Sonja Weise
EXPERIMENTAL EVALUATION OF THE HEAT TRANSFER CHARACTERISTICS OF A FLUTED TUBE USED FOR DESALINATION
International Heat Transfer Conference 11, Vol.12, 1998, issue
Ivan Catton, Thomas J. Rohloff
DIRECT CONTACT COOLING OF A CRYSTALLIZING BRINE
International Heat Transfer Conference 6, Vol.4, 1978, issue
Ruth Letan, J. Zmora
FORCED CONVECTIVE BOILING HEAT TRANSFER OF BINARY MIXTURES IN A HORIZONTAL TUBE
International Heat Transfer Conference 9, Vol.2, 1990, issue
Takamoto Saito, Eiji Hihara
HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS OF HIGH TEMPERATURE CONDENSATION OF R245FA AND R1233ZD IN A PLATE HEAT EXCHANGER
International Heat Transfer Conference 16, Vol.7, 2018, issue
Fredrik Haglind, Brian Elmegaard, Ji Zhang