Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2014010532
pages 289-304

HEAT TRANSFER ENHANCEMENT DUE TO SWIRL EFFECTS IN OVAL TUBES TWISTED ABOUT THEIR LONGITUDINAL AXIS

F. Bishara
Thermal-Fluids and Thermal Processing Laboratory, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, Ohio 45221-0072, USA
Milind A. Jog
Thermal-Fluids and Thermal Processing Laboratory, Department of Mechanical and Materials Engineering, University of Cincinnati, 2600 Clifton Ave, Cincinnati, OH 45220, USA
Raj M. Manglik
Thermal-Fluids and Thermal Processing Laboratory, Mechanical and Materials Engineering, University of Cincinnati, 2600 Clifton Ave, Cincinnati, OH 45220, USA

SINOPSIS

Periodically fully developed swirl flow and heat transfer in axially helically twisted tubes with elliptical cross sections are computationally modeled. The tubular geometry is described by its twist ratio y (ratio of 180°wist-pitch H to hydraulic diameter dh), and flow cross-section aspect ratio a (ratio of minor to major axis of ellipse). Constant-property flows of water (Prandtl number ~3.0) in the laminar Reynolds number regime (10 ≤ Re ≤ 1000) are considered for several different duct geometries (3.0 ≤ y ≤ 6.0 and 0.3 ≤ α ≤ 0.7). The parametric study delineates the effect of swirl on the velocity distribution, isothermal Fanning friction factor f, the temperature field, and Nusselt number Nu for a tube maintained at a uniform wall temperature (T condition). The dominant vortex structure has a spiral formation with a rotating fluid nucleus and two counter-rotating cells as spiral arms in the flatter section of the oval cross section. Both f and Nu are found to be highest for more tightly twisted tubes (y = 3.0) with a flatter elliptical cross section (α = 0.3). Moreover, relative to an equivalent straight oval tube, up to 2.5 times higher heat transfer rates can be achieved for fixed pumping power to render a more compact heat exchanger with a smaller volume or high surface-area density.