Journal of Enhanced Heat Transfer
Factor de Impacto: 1.406 Factor de Impacto de 5 años: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Imprimir: 1065-5131
ISSN En Línea: 1563-5074

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v4.i3.30
pages 187-201

Enhanced Heat Transfer Characteristics of Single-Phase Flows in a Plate Heat Exchanger with Mixed Chevron Plates

Arun Muley
Department of Mechanical, Industrial and Nuclear Engineering University of Cincinnati, Cincinnati, OH 45221-0072
Raj M. Manglik
Thermal-Fluids and Thermal Processing Laboratory, Mechanical and Materials Engineering, University of Cincinnati, 2600 Clifton Ave, Cincinnati, OH 45220, USA

SINOPSIS

The enhanced thermal-hydraulic performance of single-phase flows in a plate heat exchanger with mixed chevron plates is investigated experimentally. The mixed arrangement consists of plates with chevron angle β = 30° and 60°, alternatingly stacked in a single-pass, U-type, counterflow configuration. Vegetable oil (130 < Pr < 220) and water (2.4 < Pr < 4.5) are used as test fluids, with flow rates in the laminar, transition, and turbulent flow regimes (2 < Re < 6000). Results for isothermal friction factor and heat transfer under cooling conditions, along with respective correlations for laminar (2 < Re < 400) and fully developed turbulent (Re ≥ 1000) flows are presented; transition is observed to set in when Re ∼ 500. The heat transfer data are obtained from controlled experiments, employing an extension of the Wilson Plot technique. A comparison of the data with previously reported results and predictive equations for Nu and / highlights the latter’s lack of general applicability, and the need for a larger database. The relative impact of using mixed chevron plate arrangement is discussed, and their enhanced performance, in comparison with parallel-plate channels, is evaluated.


Articles with similar content:

A REVIEW ON ENHANCED HEAT TRANSFER CHARACTERISTICS OF SINGLE-PHASE FLOWS IN A PLATE HEAT EXCHANGER
Journal of Enhanced Heat Transfer, Vol.24, 2017, issue 1-6
Raj M. Manglik, Arun Muley
Experimental Investigation of Opposing Turbulent Mixed-Convection Heat Transfer in an Inclined Flat Channel with One-Sided Heating. 1. Method and Investigations for an Inclination Angle φ = 60°
Heat Transfer Research, Vol.37, 2006, issue 1
Povilas Poskas, Stasys Sinkunas, Robertas Poskas
TURBULENT MIXED CONVECTION HEAT TRANSFER IN UPWARD INCLINED FLAT CHANNEL GAS FLOW
International Heat Transfer Conference 11, Vol.7, 1998, issue
Gytis Bartkus, Povilas Poskas, Jurgis Vilemas
CONTROL IN SCALE OF GENERATED VORTEXES AT AN INPUT IN NOT ROUND INTERRUPTED DUCTS WITH THE PURPOSE OF REALIZATION OF A RATIONAL ENHANCEMENT OF CONVECTIVE HEAT EXCHANGER
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2014, issue
Victor Vasilyev, Svetlana Kotova, Svetlana Vinokurova
FLOW BOILING − A SIMPLE CORRELATION FOR CONVECTIVE HEAT TRANSFER COMPONENT
International Heat Transfer Conference 9, Vol.2, 1990, issue
V.V. Wadekar