Design and Experimental Research of a Flat-Plate Type CPL with a Porous Wick in the Condenser
SINOPSIS
A new type of a copper-methanol capillary pumped loop (CPL) with a flat-plate type of evaporator and a flat-plate type of condenser with a porous element is designed, fabricated, and tested. The multi-layer stainless steel meshes and copper meshes are adopted as a capillary structure of the evaporator and condenser, respectively. The start-up, unstable operation characteristics, and heat transfer performance are investigated experimentally. The experimental results show that when heat load is lower than 450 W the system presents good start-up and continuous operation performance. The experimental results also indicate that the CPL has a good heat transfer characteristic with thermal resistance lower than 0.026°C/W.
-
Li Huan, Liu ZhiChun, Chen BinBin, Liu Wei, Li Chen, Yang Jinguo, Development of biporous wicks for flat-plate loop heat pipe, Experimental Thermal and Fluid Science, 37, 2012. Crossref
-
Tu Zheng-kai, Pan Mu, Liu Wei, Liu Zhi-chun, Wan Zhong-min, Modeling of stability of the condensing interface in a capillary pumped loop, International Journal of Heat and Mass Transfer, 55, 5-6, 2012. Crossref