Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Journal of Enhanced Heat Transfer
Factor de Impacto: 1.406 Factor de Impacto de 5 años: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Imprimir: 1065-5131
ISSN En Línea: 1563-5074

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2011003351
pages 75-86

AN EXPERIMENTAL STUDY OF BOILING HEAT TRANSFER ENHANCEMENT OF MESH-ON-FIN TUBES

Liang-Han Chien
Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology, Taipei, 106, Taiwan
H.-L. Hwang
Department of Energy and Refrigerating Air-conditioning Engineering, National Taipei University of Technology, 1, Sec. 3, Chung-Hsaio E. Rd., Taipei 106, Taiwan

SINOPSIS

This study investigated a new enhanced boiling surface made by wrapping wire mesh on low-fin tubes. Pool boiling performance of the new enhanced tubes was tested with refrigerant 134a at 5,10, and 26.67°C saturation temperature for 6−48 kW/m2 heat flux. Brass or copper mesh of 80,100, or 120 mesh per inch was wrapped around finned tubes of 42, 50, or 60 FPI (fins per inch). The fin heights were either 0.2 mm or 0.4 mm. The test results show that mesh-covered fin tubes yielded significantly enhanced boiling performance. The influence of fin geometry is more pronounced with mesh than without mesh. The preferred mesh size decreases with decreasing heat flux. The surface made by wrapping brass mesh of 100 mesh per inch on 60 FPI tube having 0.4 mm fin height yielded the best boiling performance. It enhanced the boiling heat transfer coefficient by 3−8 fold at 5−26.7°C as compared with the smooth tube.


Articles with similar content:

EXPERIMENTAL STUDY OF POOL BOILING ON PIN-FINNED AND STRAIGHT-FINNED SURFACES ON AN INCLINED PLATE IN FC-72
Journal of Enhanced Heat Transfer, Vol.18, 2011, issue 4
Liang-Han Chien, Shu-Che Lee
Brazed Aluminum Condensers for Residential Air Conditioning
Journal of Enhanced Heat Transfer, Vol.8, 2001, issue 1
Hyunuk Lee, Ralph L. Webb
CONDENSATION HEAT TRANSFER AND PRESSURE DROP OF R-410A IN THREE 7.0MM OUTER DIAMETER MICROFIN TUBES HAVING DIFFERENT INSIDE GEOMETRIES
Journal of Enhanced Heat Transfer, Vol.20, 2013, issue 3
H. W. Byun, J. K. Lee, Nae-Hyun Kim
Compound Augmentation of Pool Boiling on Three Selected Commercial Tubes
Journal of Enhanced Heat Transfer, Vol.7, 2000, issue 5
Michael M. Ohadi, J. Darabi, Serguei V. Dessiatoun
HEAT TRANSFER AND PRESSURE DROP DURING EVAPORATION AND CONDENSATION OF R134a INSIDE TWO MICROFIN TUBES OF NEW DESIGN
International Heat Transfer Conference 13, Vol.0, 2006, issue
Alfonso Niro, Andrea Lucchini, Luigi Pietro Maria Colombo, Adriano Muzzio