Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Journal of Enhanced Heat Transfer
Factor de Impacto: 0.562 Factor de Impacto de 5 años: 0.605 SJR: 0.211 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimir: 1065-5131
ISSN En Línea: 1026-5511

Volumes:
Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v15.i1.20
pages 17-30

Air Side Performance of a Novel Lanced Fin and Flat Tube Heat Exchanger

Junqi Dong
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai
Jiangping Chen
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai
ZhiJiu Chen
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai
Yimin Zhou
Zhejing Yinlun Machine Co., Ltd., Zhejiang, Shanghai

SINOPSIS

A total of nine cross-flow heat exchangers having a novel lanced fin and a flat tube were studied experimentally. A series of tests were conducted for the air side Reynolds number based on the lanced fin hydraulic diameter in the range of 800 to 6500 with different fin spaces and fin lengths, at a constant tube-side water flow rate of 2.8 m3/h. The air side thermal performance data were analyzed using the effectiveness-NTU method. The characteristics of heat transfer and pressure drop for different geometric parameters were reported in terms of the Colburn j-factor and the Fanning friction factor f, as a function of Re. The effects of fin spaces and fin lengths on heat transfer and pressure drop were examined. The general correlations for j and f factors were derived by multiple linear regression analysis and F test of significance. The correlations for j and f factors can predict 95% of the experimental data within ±10%. Further, two comparison methods were adopted to evaluate on the whole the air side thermal hydraulic performance of the novel lanced fins.


Articles with similar content:

Air Side Performance of Brazed Aluminum Heat Exchangers
Journal of Enhanced Heat Transfer, Vol.3, 1996, issue 1
Yu-Juei Chang, Chi-Chuan Wang
HEAT, MASS АND MOMENTUM TRANSFER CHARACTERISTICS OF AN AIR COOLING AND DEHUMIDIFYING COIL
International Heat Transfer Conference 6, Vol.4, 1978, issue
S. Nagaraja , M. V. Krishna Murthy
NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE SHELL SIDE CHARACTERISTICS OF THE TREFOIL-HOLE BAFFLE HEAT EXCHANGER
Heat Transfer Research, Vol.48, 2017, issue 1
Minshan Liu , Caipeng Bai, Ke Wang, Yongqing Wang, Dan Wang
Particulate Fouling of Water in Internal Helical-rib Roughness Tubes
International Heat Transfer Conference 12, Vol.53, 2002, issue
Arthur E. Bergles, Wei Li, Ralph L. Webb
BRAZED ALUMINUM HEAT EXCHANGERS AND THEIR AIR SIDE PERFORMANCE
Journal of Enhanced Heat Transfer, Vol.24, 2017, issue 1-6
Yu-Juei Chang, Chi-Chuan Wang