Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v12.i1.10
pages 1-20

Heat Transfer and Pressure Drop Characteristics of Finned Tube Banks in Forced Convection (Comparison of Heat Transfer and Pressure Drop Characteristics of Serrated and Spiral Fins)

Kiyoshi Kawaguchi
Faculty of Engineering, Toyama University, Gofuku 3190, Toyama-shi, Toyama, 930-8555 Japan
Kenichi Okui
Faculty of Engineering, Toyama University, Gofuku 3190, Toyama-shi, Toyama, 930-8555 Japan
Takaharu Kashi
Faculty of Engineering, Toyama University, Gofuku 3190, Toyama-shi, Toyama, 930-8555 Japan

SINOPSIS

In recent years, requirement for the reduction of energy consumption has been increasing to solve the problems of global warming and shortage of petroleum resources. In the power generation field, thermal power generation occupies 60% of the power generation demand, so the improvement of thermal efficiency is of considerable importance. In this article, the heat transfer and pressure drop characteristics of finned tube banks used for heat exchangers in thermal power generation plants were studied experimentally. Serrated finned tube banks for improvement of higher heat transfer and conventional spiral finned tube banks were tested under the same test conditions. Empirical equations to predict the heat transfer coefficient and the pressure drop were proposed.


Articles with similar content:

HEAT TRANSFER AND PRESSURE DROP OF FINNED TUBE BANKS WITH STAGGERED ARRANGEMENT IN FORCED CONVECTION
International Heat Transfer Conference 10, Vol.25, 1994, issue
Masayuki Fukagawa, T. Motai , Makio Iwabuchi, M. Kanzaka, Tetsuya Matsuo
Condensation heat transfer and pressure drop inside channels for AC/HP application
International Heat Transfer Conference 12, Vol.1, 2002, issue
Luca Doretti, Luisa Rossetto, Giuseppe Censi, Giovanni Antonio Longo, Alberto Cavallini, Davide Del Col
NUMERICAL MODELING AND PERFORMANCE INVESTIGATION FOR COMPACT HEAT EXCHANGERS IN DIFFERENT FIN ARRANGEMENT AND FLUID FLOW CONDITIONS
Computational Thermal Sciences: An International Journal, Vol.8, 2016, issue 5
Waleed Abdelmaksoud, Mahmoud A. Kassem
Transient Models to Analyze the Influence of the Air Velocity and Ducts Diameter on the Performance of Earth-Air Heat Exchangers
International Journal of Fluid Mechanics Research, Vol.43, 2016, issue 5-6
Luiz Alberto O. Rocha, L. A. Isoldi, E. D. dos Santos, R. S. Brum, J. V. A. Ramalho
PROMISING TRENDS IN DESIGNING EFFECTIVE HEAT TRANSFER SURFACES
Transport Phenomena in Thermal Engineering. Volume 2, Vol.0, 1993, issue
Guenrikh A. Dreitser