Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Plasma Medicine
SJR: 0.278 SNIP: 0.183 CiteScore™: 0.57

ISSN Imprimir: 1947-5764
ISSN En Línea: 1947-5772

Plasma Medicine

DOI: 10.1615/PlasmaMed.2014011720
pages 1-10

Comparative Study on the Use of Different Metal Electrodes in Low-Pressure Glow Discharge Plasma Sterilization

Joanna Abigael Daseco
Plasma Physics Laboratory, National Institute of Physics, University of the Philippines, Diliman Quezon City 1101, Philippines
Karel G. Pabelina
Plasma Physics Laboratory, National Institute of Physics, University of the Philippines, Diliman Quezon City 1101, Philippines
Ma. Auxilia T. Siringan
Microbiological Research and Services Laboratory, Natural Science and Research Institute, University of the Philippines, Diliman Quezon City 1101, Philippines
Henry J. Ramos
Plasma Physics Laboratory, National Institute of Physics, University of the Philippines, Diliman Quezon City 1101, Philippines

SINOPSIS

The sterilizing efficacy of low-pressure direct current glow discharge hydrogen peroxide (H2O2) plasma generated by a planar parallel plate plasma source using the plasma enhanced chemical vapor deposition (PECVD) facility was tested. This study compares the effect of using different metals (copper, stainless steel, and aluminum) as electrodes in plasma sterilization of stainless steel dishes. Test samples were exposed to H2O2 plasma under different sets of discharge currents and exposure times. Bacillus subtilis was used as the test organism and microbial analysis was made by means of the standard plate count method of serial dilution and pour plating. Evaluation of microbial death was done using survival curves, percent reduction, and decimal reduction value. Results showed that sterilization using copper electrodes exhibited the highest decimal reduction value (D-value) and percent reduction among the three electrodes. However, statistical analysis using multivariate analysis of variance (MANOVA) at 0.05 significance level assessed that the type of electrode material is not a significant factor in the H2O2 plasma sterilization of Bacillus subtilis cells.


Articles with similar content:

Effect of Oxygen on Decontamination of Cumin Seeds by Atmospheric Pressure Dielectric Barrier Discharge Plasma
Plasma Medicine, Vol.6, 2016, issue 3-4
Kyana Mohammadi, Soheila Abdi, Davoud Dorranian
Selective Cytotoxic Activity of Se-Methyl-Seleno-L-Cysteine– and Se-Polysaccharide–Containing Extracts from Shiitake Medicinal Mushroom, Lentinus edodes (Agaricomycetes)
International Journal of Medicinal Mushrooms, Vol.19, 2017, issue 8
Maciej Dawidowski, Iwonna Rahden-Staroń, Marzenna Klimaszewska, Jadwiga Turło, Agnieszka Szczepanska, Dagmara Kurpios-Piec, Emilia Orzechowska, Piotr Podsadni, Emilia Grosicka-Maciag, Sandra Górska
Mycelial Growth of Pleurotus ostreatus (Jacq.: Fr.) Kumm. and Lentinus edodes (Berk.) Sing. on Selenium-Enriched Media
International Journal of Medicinal Mushrooms, Vol.3, 2001, issue 2-3
Jelena Vukojević, Sonja Duletic-Lausevic, Ivanka Milenkovic, Mirjana Stajic
Effect of Plasma Damage by PECVD Silicon Nitride Deposition on the Performance of Silicon Inversion Layer Solar Cells
Progress in Plasma Processing of Materials, 1999, Vol.1, 1999, issue
M. Rammensee, R. Hezel, R. Auer
THEORETICAL JUSTIFICATION OF AN EFFECTIVE CRYOPRESERVATION PROTOCOL OF CANDIDA YEASTS AND EXPERIMENTAL VERIFICATION OF THE MATHEMATICAL MODELING RESULTS
Telecommunications and Radio Engineering, Vol.74, 2015, issue 14
A. Artuyants, I. Vysekantsev