Volumen 29, 2019 Volumen 28, 2018 Volumen 27, 2017 Volumen 26, 2016 Volumen 25, 2015 Volumen 24, 2014 Volumen 23, 2013 Volumen 22, 2012 Volumen 21, 2011 Volumen 20, 2010 Volumen 19, 2009 Volumen 18, 2008 Volumen 17, 2007 Volumen 16, 2006 Volumen 15, 2005 Volumen 14, 2004 Volumen 13, 2003 Volumen 12, 2002 Volumen 11, 2001 Volumen 10, 2000 Volumen 9, 1999 Volumen 8, 1998 Volumen 7, 1997 Volumen 6, 1996 Volumen 5, 1995 Volumen 4, 1994 Volumen 3, 1993 Volumen 2, 1992 Volumen 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v15.i4.50
pages 423-438

SUPPRESSION OF AEROSOL GENERATION DURING SPRAYING AND DEPOSITION OF CONSUMER PRODUCTS

D. Ken Giles
Department of Biological and Agricultural Engineering, University of California—Davis, Bainer Hall, One Shields Avenue, Davis, CA 95616, USA
Daniel Downey
Bio & Ag Eng, UC Davis
H. Scher
Department of Biological and Agricultural Engineering, University of California—Davis, Bainer Hall, One Shields Avenue, Davis, CA 95616
D. Winetzky
Genencor International, Palo Alto, CA 94304
T. Becker
Genencor International, Palo Alto, CA 94304
J. Hogue
Genencor International, Palo Alto, CA 94304

SINOPSIS

This study investigated droplet-size spectra and aerosol production from consumer products dispensed by disposable trigger sprayers for deposition on household surfaces. A strategy was devised to reduce the generation of small, mobile droplets through nozzle selection and manipulation of fluid properties. Parametric experiments with a generic laundry stain remover ("prespotter"), five spray dispenser designs, and four concentrations of a long-chain polymer were conducted. Surface tension of the test formulations ranged from 0.0350 to 0.0365 N/m. Shear viscosities ranged from 258 to 165 cps (shear rate of 7.5 s−1) and 66 to 48 cps (shear rate of 75 s−1). Polymer concentrations ranged from 0.00% to 0.10% w/w. Elongational viscosity characteristics were measured using a modified flow technique modeled after R. W. Dexter [14]. Droplet size spectra of the spray discharged from dispensers were measured with a laser-diffraction system. Design of the trigger spray nozzle significantly affected the droplet size spectra. For all trigger sprayers studied, addition of polymer to the spray formulation significantly reduced the generation of aerosol droplets. Mass transfer studies confirmed that addition of polymer reduced airborne spray aerosols by 86% to 94%. Similarly, addition of the polymer reduced the generation of mobile aerosols from spray impaction on target surfaces by 47−98%, depending on nozzle design and target surface characteristics.


Articles with similar content:

NEWTONIAN AND NON-NEWTONIAN SPRAY INTERACTION WITH A HIGH-SPEED MOVING SURFACE
Atomization and Sprays, Vol.19, 2009, issue 1
Martin H. Davy, Larry Li, Donald T. Eadie, Sheldon I. Green, Daniel M. Dressler
EFFECTS OF ELASTICITY ON THE SPRAYING OF A NON-NEWTONIAN FLUID
Atomization and Sprays, Vol.18, 2008, issue 3
Graham M. Harrison, Gyo Y. Park
FLUID VELOCITY AND SHEAR IN ELLIPTIC-ORIFICE SPRAY NOZZLES
Atomization and Sprays, Vol.5, 1995, issue 3
Andrew C. Chapple, R. D. Brazee, C. R. Krause, R. D. Fox, H. Zhu, D. L. Reichard
SPRAY CONE ANGLES OF EFFERVESCENT ATOMIZERS
Atomization and Sprays, Vol.4, 1994, issue 3
Arthur H. Lefebvre, S. Kevin Chen
CHARACTERIZATION OF HYDRAULIC NOZZLES FOR DROPLET SIZE AND SPRAY COVERAGE
Atomization and Sprays, Vol.22, 2012, issue 8
H. Erdal Ozkan, Peter Ling, Heping Zhu, Huseyin Guler