Volumen 29, 2019 Volumen 28, 2018 Volumen 27, 2017 Volumen 26, 2016 Volumen 25, 2015 Volumen 24, 2014 Volumen 23, 2013 Volumen 22, 2012 Volumen 21, 2011 Volumen 20, 2010 Volumen 19, 2009 Volumen 18, 2008 Volumen 17, 2007 Volumen 16, 2006 Volumen 15, 2005 Volumen 14, 2004 Volumen 13, 2003 Volumen 12, 2002 Volumen 11, 2001 Volumen 10, 2000 Volumen 9, 1999 Volumen 8, 1998 Volumen 7, 1997 Volumen 6, 1996 Volumen 5, 1995 Volumen 4, 1994 Volumen 3, 1993 Volumen 2, 1992 Volumen 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v15.i5.40
pages 545-566

INFLUENCE OF INERT SPRAYS ON EXTINCTION OF PREMIXED FLAMES PROPAGATING IN A DUCT WITH VARYING CROSS-SECTIONAL AREA

Chih-Hsin Tsai
Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan 70101, Republic of China
Ta-Hui Lin
Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan ; Research Center for Energy Technology and Strategy, National Cheng Kung University, Tainan 70101, Taiwan

SINOPSIS

The extinction of a premixed flame propagating in a duct with varying cross-sectional area under the influences of flame stretch, preferential diffusion, and water sprays is analyzed using activation energy asymptotics. A completely prevaporized mode and a partially prevaporized mode are identified on the basis of a critical value of the initial droplet size (rc′) for completing the vaporization process at the flame. The liquid loading and droplet size of the water spray induces internal heat loss through liquid vaporization. It is found that the burning intensity of a flame with water sprays is reduced with increasing liquid loading or decreasing initial droplet size, independent of the value of Lewis number (Le). Small droplets can absorb heat from the flame more effectively than large ones. However, it is not beneficial to reduce droplet size below the critical initial droplet size. The negative (or positive) stretch weakens (or strengthens) a Le < 1 flame but intensifies (or reduces) a Le > 1 flame. A positively stretched flame with Le > 1 or a negatively stretched flame with Le < 1 can be extinguished by increasing the effect of stretch, and this behavior is characterized by a C-shaped extinction curve. For a Le < 1 flame enduring positive stretch or a Le > 1 flame experiencing negative stretch, extinction does not occur for the completely prevaporized mode. However, for the partially prevaporized mode, the S-shaped extinction curve occurs if the liquid-loading water is large enough and the droplet size is also sufficiently large. Note that extinction characterized by a C-shaped curve is dominated by flame stretch; whereas extinction, characterized by an S-shaped curve, is governed by internal heat loss.