Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
International Journal of Energy for a Clean Environment
SJR: 0.195 SNIP: 0.659 CiteScore™: 1.2

ISSN Imprimir: 2150-3621
ISSN En Línea: 2150-363X

International Journal of Energy for a Clean Environment

Formerly Known as Clean Air: International Journal on Energy for a Clean Environment

DOI: 10.1615/InterJEnerCleanEnv.2017022821
pages 161-174

COMPARATIVE ANALYSIS OF DIFFERENT REFRIGERANTS USED IN A HIGH-TEMPERATURE VAPOR-COMPRESSION HEAT PUMP

V. V. Karnaukh
Donetsk National University of Economics and Trade named after Mykhailo Tugan-Baranovsky, 21 Shchorsa Str., Donetsk, 83050, Ukraine
Alexey B. Birukov
Donetsk National Technical University, 2 Shybankova Sq., Pokrovsk, 85300, Donetsk Region, Ukraine
Victor A. Mazur
Odessa National Academy of Food Technologies, 112 Kanatnaya Str., Odessa, 65000, Ukraine
K. A. Rzhesik
Donetsk National University of Economics and Trade named after Mykhailo Tugan-Baranovsky, 21 Shchorsa Str., Donetsk, 83050, Ukraine

SINOPSIS

Water is used as a cooling agent in different industrial installations. The heat accumulated with the cooling water is transferred to the environment by heat exchangers. At the same time, heating of industrial and administrative buildings is necessary in cold seasons. Using the heat of the cooling water for heating purposes is an attractive idea. However, this is a low-potential source of heat. Cooling water heat utilization is possible with the help of a high-temperature heat pump. The vapor-compression type of the heat pump is considered. Four refrigerants are selected for the analysis: R142b, R236fa, R600a, and R406a. The computational research is carried out of the high-temperature pump efficiency depending on the refrigerant used. The calculation results for the heat pump thermodynamic cycle with refrigerants selected are presented. The high-temperature heat pump coefficient of performance for heating is shown depending on low-temperature source level for two values of the condensation point temperature: 60°C and 83°C. As a result of the analysis, the refrigerants R236fa and R600a are recommended for being used in a high-temperature heat pump for utilizing the heat of industrial cooling water.


Articles with similar content:

OPTIMIZATION OF GAS PROCESSING IN A HIGH-TEMPERATURE PROTON EXCHANGE MEMBRANE FUEL CELL COMBINED HEAT AND POWER PLANT ON THE BASIS OF THE NUMERICAL PINCH METHOD
International Journal of Energy for a Clean Environment, Vol.11, 2010, issue 1-4
Dimosthenis Trimis, H. Krause, J. Nitzsche, Stephan Anger
COMPARATIVE STUDY OF THE PERFORMANCE OF TWO GREENHOUSE HEATING TECHNIQUES: SOLAR AIR HEATER AND HEAT PUMP
Heat Transfer Research, Vol.50, 2019, issue 12
Abdelwahed Ghorbel, Salwa Bouadila, Hassen Boughanmi, Asma Ben Salem-Fnayou, Douja Sellami
HEAT PUMPS FOR MOLTEN SALT ENERGY STORAGE
Second Thermal and Fluids Engineering Conference, Vol.17, 2017, issue
William Culbreth, M. Ramos Gonzalez
SOME PROBLEMS OF DESIGN RELATED TO THE ASSESSMENT OF THE ENERGY EFFICIENCY OF HIGH-TEMPERATURE AIR PUMPS
Heat Pipe Science and Technology, An International Journal, Vol.7, 2016, issue 3-4
Henryk Charun, Waldemar Kuczynski, Tadeusz Bohdal
Desalination of Seawater by the Energy-Saving Membrane Distillation Method
Heat Transfer Research, Vol.36, 2005, issue 3
M. Sukher, S. P. Rudobashta