%0 Journal Article %A Gasiunas, Stasys %A Seporaitis, Marijus %A Cesna, Benediktas B. %A Valincius, Mindaugas %A Pabarcius, Raimondas %A Laurinavicius, Darius %D 2011 %I Begell House %K shear at steam-water interface, co-current steam-water flow, horizontal channel, steam velocity profile %N 7 %P 629-643 %R 10.1615/HeatTransRes.v42.i7.30 %T Interfacial Shear of Co-Current Steam−Water Flow Estimation − I. Single-Phase FLUENT Model in Conjunction with Measured Total Increment of Water Temperature and Steam Velocity Profile Data %U https://www.dl.begellhouse.com/journals/46784ef93dddff27,462757cb7131d81f,6b5a46a66e5ad60d.html %V 42 %X The results of condensation implosion tests (Almenas et al., 2006) and slug flow occurrence (Chun and Yu, 2000) lead to the conclusion that condensation may have some serious impact on steam−liquid interface stability. To explore this in detail a special test facility was constructed and the FLUENT 3D model (single phase with condensation simulation) is developed at the Lithuanian Energy Institute. The following investigation seeks to determine the condensation influence on the stability of a horizontal two-phase flow interface, and the overall purpose of the program is to employ transitional behaviors with positive feedback between momentum and energy transfer in real systems. This paper presents the LEI experimental test facility and methodology of the experiments whose results were employed to adopt and verify the FLUENT 3D model. Preliminary simulation results show that the boundary layer thickness and also interfacial shear strongly depend on condensation. %8 2012-03-06