Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN Imprimer: 1050-6934
ISSN En ligne: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v10.i4.20
14 pages

Anterior Cruciate Ligament Reconstruction with the Leeds-Keio Artificial Ligament

Kyosuke Fujikawa
Knee Disease Centre, Ohtsuki Hospital for Surgery, Tokyo; Professor of Orthopaedic Surgery. Department of Orthopredic Surgery National Defense Medical College, Saitama, Japan
Tatsuo Kobayashi
Department of Orthopaedic Surgery, National Defense Medical Collage, 3-2 Namiki, Tokorozawa, Saitama, 359-8513, Japan
Yoshihiro Sasazaki
Department of Orthopaedic Surgery, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama, 359-8513, Japan
Hideo Matsumoto
Department of Orthopaedic Surgery, School of Medicine, Keio University, Tokyo, Japan
Bahaa B. Seedhom
Rheumatology and Rehabilitation Research Unit, University of Leeds, 36 Clarendon Road, Leeds LS 2 9NZ, NK

RÉSUMÉ

The Leeds-Keio (L-K) artificial ligament, developed for knee ligament reconstruction, is made of polyester with a maximum tensile strength of 2200 N. This implant works not only as a ligament but also as a scaffold onto which natural tissue grows from synovium. In an animal experiment, each strand of the L-K ligament was covered with new tissue by 2-3 weeks after anterior cruciate ligament reconstruction. Eight weeks postoperatively, abundant fibrous tissue with extensive vascularity covered the implant, which was still histologically immature. After 16 weeks, vascularization and tissue induction began to subside, and histologic analysis showed dense fibers running longitudinally and parallel. By 36 weeks, the new ligament looked like a natural anterior cruciate ligament, although histologically more cells could be seen than in the natural ligament. This maturation was observed only when the substitute was implanted under good tension. Clinically, the surgical procedure has been improved over the past 10 years, to the current practice in which the tape-in-tube double L-K ligament employs a small piece of autogenous tissue to promote early tissue induction and maturation. Using this practice (n = 135), more than 85% of the patients were satisfied subjectively, objectively, and arthroscopically at the 5-year postoperative FU period. Few patients had joint effusion postoperatively. Sacrifice of autogenous tissue is minimal. The patient can return to activities of daily living within 2 weeks, and more than 50% of them to sports within 10 weeks, and the new ligament is expected to keep its function for a long period as ingrowth completes the structure biologically.


Articles with similar content:

Anterior Cruciate Reconstruction with Bioactive Leeds-Keio Ligament (LKII): Preliminary Report
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 1
Yoshihiro Aoki, Toshiyuki Kikuchi, Atsushi Sugihara, Koichi Nemoto, Hideaki Murakami, Kyosuke Fujikawa, Satoshi Tsukazaki, Hironobu Watanabe, Masashi Matsunaga
Failure of a Medial Unicompartmental Knee Replacement due to Metal Allergy
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 4
Shamsul Khan, Theodore Balfousias, George Tselentakis, Bala Srikanth, Alexandros P. Apostolopoulos
Comparative Evaluation of Bone Formation between PRF and Blood Clot Alone as the Sole Sinus-Filling Material in Maxillary Sinus Augmentation with the Implant as a Tent Pole: A Randomized Split-Mouth Study
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Gurumoorthy Kaarthikeyan, N. D. Jayakumar, D. Sivakumar
Histologic and Histomorphometric Analysis of an Immediately Loaded Implant Retrieved from Man after 14 Months of Loading
Journal of Long-Term Effects of Medical Implants, Vol.15, 2005, issue 5
Giovanna Iezzi, Antonio Scarano, Marco Degidi, Adriano Piattelli
The Outcome and Complications of ACL Reconstruction Augmented with a Ligament Augmentation Device for a Follow-up Period of More Than Five years
Journal of Long-Term Effects of Medical Implants, Vol.10, 2000, issue 3
Ichiro Sekiya, Yusuke Sakaguchi, Haruyasu Yamamoto, Kenichi Shinomiya, Takeshi Muneta